
RT2 HT First Strand Kit
- Rapid and efficient first-strand cDNA synthesis
- Complete elimination of genomic DNA
- Results with as little as 25 ng total RNA per reaction
- cDNA is immediately ready for real-time PCR
- External RNA control to monitor enzyme inhibitors
The RT² HT First Strand Kit provides a rapid and convenient procedure for efficient first-strand cDNA synthesis and genomic DNA elimination in RNA samples. It enables simultaneous and easy parallel processing of 96 RNA samples for reverse transcription. The synthesized cDNA is ready to use in real-time PCR expression analysis of multiple genes.
- Buy Products
- Product Details
Buy Products
Cat No./ID:330411 RT² HT First Strand Kit (96) $594.00 RT2 HT First Strand Kit |
Product Details
The RT2 HT First Strand Kit provides a rapid and convenient procedure for efficient cDNA synthesis from mRNA for use in gene expression assays.
The kit includes a proprietary procedure to effectively eliminate contaminating genomic DNA from RNA samples before reverse transcription. Random hexamers and oligo-dT primers prime reverse transcription in an unbiased manner, and a reverse transcriptase synthesizes cDNA product with optimal yield and length. A built-in external RNA control helps monitor reverse transcription efficiency and test for enzyme inhibitors. The RT2 HT First Strand Kit is optimized for real-time PCR-based gene expression analysis using RT2 Profiler PCR Arrays and RT2 qPCR Primer Assays, and can be successfully used with other commercially available gene expression analysis assays.
Each sample is mixed with the proprietary Buffer GE2 in separate wells of a 96-well plate. The plate is sealed using the sealing film provided and incubated on a thermal cycler. After addition of the master mix (BC4 Reverse Transcriptase Mix), the sample is then reverse transcribed using any thermal cycler. The transcribed cDNA is immediately ready for use in downstream applications. We recommend RT² Profiler PCR Arrays or RT² qPCR Primer Assays for further analysis.
The RT² HT First Strand Kit yields results with as little as 25 ng or as much as 5 µg total RNA per reaction. However, the optimal amount of starting material depends on the relative abundance of the transcripts of interest. Lower abundance transcripts require more RNA; higher abundance transcripts require less RNA. Greater amounts of input RNA yield greater number of positive calls (i.e., gene expression detection) in the linear dynamic range of the method.
Product Resources
Customers who bought these products also bought
- Cat No./ID:330603
RT² SYBR Green FAST Mastermix (24)
Contains 24 x 1.35 mltubes: for 24 x 100-well ring discs on the QIAGEN Rotor-Gene Q or 3000 x 20 µl reactions$1,684.00Add To Cart - Cat No./ID:330501
RT² SYBR Green qPCR Mastermix (8)
Contains 8 x 1.35 ml tubes: for 8 x 96-well RT² PCR Arrays, 4 x 384-well RT² PCR Arrays or 800 x 25 µl reactionsor 2000 x 10µlreactions$779.00Add To Cart - Cat No./ID:330421
RT2 Easy First Strand Kit (12)
RT2 EZ First Strand Kit$241.00Add To Cart - Cat No./ID:330500
RT² SYBR Green qPCR Mastermix (2)
Contains 2 x 1.35 ml tubes: for 2 x 96-well RT² PCR Arrays, 1 x 384-well RT² PCR Arrays or 200 x 25 µl reactionsor 400 x 10µl reactions$210.00Add To Cart - Cat No./ID:330001
RT2 qPCR Primer Assay (200)
RT2 qPCR Primer AssaySelect Targets - Cat No./ID:338112
Human XpressRef Universal Total RNA
2 tubes each containing 100 μg Human XpressRef Universal Total RNA$317.00Add To Cart - Cat No./ID:215011
FastLane Cell cDNA Kit (50)
Buffer FCW, Buffer FCP, and components for 50 x 20 µl reverse-transcription reactions (gDNA Wipeout Buffer, Quantiscript Reverse Transcriptase, Quantiscript RT Buffer, RT Primer Mix, and RNase-Free Water)$675.00Add To Cart - Cat No./ID:330523
RT² SYBR Green ROX qPCR Mastermix (24)
Contains 24 x 1.35 mltubes: for 24 x 96-well RT² PCR Arrays, 16 x 384-well RT² PCR Arrays or 2400 x 25 µl reactionsor 6000 x 10 µl reactions$1,692.00Add To Cart - Cat No./ID:330504
RT² SYBR Green qPCR Mastermix (6)
Contains 6 x 1.35 ml tubes: for 6 x 96-well RT² PCR Arrays, 3 x 384-well RT² PCR Arrays or 600 x 25 µl reactionsor 1500 x 10µl reactions$612.00Add To Cart - Cat No./ID:330524
RT² SYBR Green ROX qPCR Mastermix (6)
Contains 6 x 1.35 ml tubes: for 6 x 96-well RT² PCR Arrays, 3 x 384-well RT² PCR Array or 600 x 25 µl reactionsor 1500 x 10 µl reactions$618.00Add To Cart - Cat No./ID:330502
RT² SYBR Green qPCR Mastermix (12)
Contains 12 x 1.35 ml tubes: for 12 x 96-well RT² PCR Arrays, 8 x 384-well RT² PCR Arrays or 1200 x 25 µl reactionsor 3000 x 10 µl reactions$1,156.00Add To Cart - Cat No./ID:330522
RT² SYBR Green ROX qPCR Mastermix (12)
Contains 12 x 1.35 ml tubes: for 12 x 96-well RT² PCR Arrays, 8 x 384-well RT² PCR Arrays or 1200 x 25 µl reactionsor 3000 x 10 µl reactions$1,128.00Add To Cart - Cat No./ID:218075
miScript SYBR Green PCR Kit (1000)
For 1000 reactions: QuantiTect SYBR Green PCR Master Mix, miScript Universal Primer$2,068.00Add To Cart - Cat No./ID:1011132
Buffer RDD
35 ml Buffer RDD and 7 ml RNase-free water$87.60Add To Cart - Cat No./ID:330503
RT² SYBR Green qPCR Mastermix (24)
Contains 24 x 1.35 ml tubes: for 24 x 96-well RT² PCR Arrays, 16 x 384-well RT² PCR Arrays or 2400 x 25 µl reactionsor 6000 x 10 µl reactions$1,684.00Add To Cart - Cat No./ID:338162
RT2 PCR Array Loading Reservoir (12)
12 x 5 ml capacity, irradiation-sterilized RT2 PCR Array Loading Reservoirs$24.90Add To Cart - Cat No./ID:330404
RT2 First Strand Kit (50)
For fifty 20 µl first strand cDNA synthesis reactions; Buffer GE (100 µl), 5x Buffer BC3 (200 µl), RE3 Reverse Transcriptase Mix (100 µl), Control P2 (50 µl), Nuclease-Free Water (1 ml)$506.00Add To Cart