
QIAseq Multimodal Panels
- Complete system to go from total nucleic acids to a sequencing-ready library using a single-day workflow
- Error correction with Unique Molecular Indices (UMIs) to enhance NGS panel sensitivity
- A single-primer extension (SPE) approach that overcomes the limitations of 2-primer amplicon approaches on amplicon size and primer multiplexing
- Unique Dual Indices (UDIs) to reduce sample index hopping
- Sample to Insight solution for consolidated targeted DNA and RNA sequencing
QIAseq Multimodal Panels have been developed for consolidated targeted DNA and RNA enrichment and analyses. Unlike current approaches, QIAseq Multimodal Panels do not require 2 separate workflows for DNA and RNA analysis – saving time and conserving samples that are of limited availability.
- Buy Products
- Product Details
Buy Products
Cat No./ID:333932 QIAseq Multimodal Panel (12) $3,024.00 Kit containing ALL reagents (except indices) sufficient to process 12 samples for multimodal (DNA and RNA) sequencing; fixed small panel for a total of 24 reactions |
Cat No./ID:333935 QIAseq Multimodal Panel (96) $17,630.00 Kit containing ALL reagents (except indices) sufficient to process 96 samples for multimodal (DNA and RNA) sequencing; fixed small panel for a total of 192 reactions |
Cat No./ID:333942 QIAseq Multimodal HC Panel (12) $8,388.00 Kit containing ALL reagents (except indices) sufficient to process 12 samples for multimodal (DNA and RNA) sequencing; fixed high content (HC) panel for a total of 24 reactions |
Cat No./ID:333945 QIAseq Multimodal HC Panel (96) $63,744.00 Kit containing ALL reagents (except indices) sufficient to process 96 samples for multimodal (DNA and RNA) sequencing; fixed high content (HC) panel for a total of 192 reactions |
Cat No./ID:333962 QIAseq Multimodal Index I (12) $800.00 Box containing indices, enough to process a total of 12 samples, for indexing up to a total of 12 samples for QIAseq Multimodal Panel sequencing on Illumina platforms |
Cat No./ID:333965 QIAseq Multimodal Index I Set A (96) $3,022.00 Box containing indices, enough to process a total of 96 samples, for indexing up to a total of 96 samples for QIAseq Multimodal Panel sequencing on Illumina platforms; 1 of 2 sets required for multiplexing 192 samples |
Cat No./ID:333975 QIAseq Multimodal Index I Set B (96) $3,022.00 Box containing indices, enough to process a total of 96 samples, for indexing up to a total of 96 samples for QIAseq Multimodal Panel sequencing on Illumina platforms; 2 of 2 sets required for multiplexing 192 samples |
Cat No./ID:333985 QIAseq Multimodal Index I Set A SW (96) $3,022.00 Box containing indices, enough to process a total of 96 samples, for indexing up to a total of 96 samples for QIAseq Multimodal Panel sequencing on Illumina platforms using the optional separate workflows; 1 of 2 sets required for multiplexing 192 samples |
Cat No./ID:333995 QIAseq Multimodal Index I Set B SW (96) $3,022.00 Box containing indices, enough to process a total of 96 samples, for indexing up to a total of 96 samples for QIAseq Multimodal Panel sequencing on Illumina platforms using the optional separate workflows; 2 of 2 sets required for multiplexing 192 samples |
Product Details
Recent advances in NGS chemistries, platforms, and bioinformatics pipelines are enabling users to efficiently interrogate biological samples for changes in DNA and RNA. Current approaches, however, require the use of 2 separate workflows to prepare libraries from separate DNA and RNA isolates. Limitations of such approaches include:
- Large amounts of sample material required for generating sufficient amounts of input DNA and RNA for multiple workflows
- Added complexity of deriving integrated insights from results of different technical approaches, each with its own innate bias
- Inefficient use of resources
- Long turn-around times
To overcome the limitations associated with current approaches, QIAseq Multimodal Panels start with total nucleic acids (or DNA + RNA) and prepares UDI-containing, Illumina-compatible targeted DNA and RNA libraries using a single-day, consolidated workflow. In addition, QIAseq Multimodal Panels have been designed for use with low-yield and poor-quality biological samples.
Workflow of the QIAseq Multimodal Panels
The QIAseq Multimodal Panel workflow can be used to prepare sequencing-ready libraries in a single day. The library insert size is approximately 150 bp, making the QIAseq Multimodal Panels highly compatible with low-quality samples, such as FFPE samples.
Robust detection of DNA and RNA biomarkers
QIAseq Multimodal Panels can be used to reliably detect DNA and RNA biomarkers using a consolidated workflow from total nucleic acids. The ability of QIAseq Multimodal Panels to simultaneously detect DNA and RNA biomarkers has been benchmarked against two separate workflows (namely, QIAseq Targeted DNA and QIAseq Targeted RNAscan Panels).
QIAseq Multimodal Panels can be used to interrogate different types of biomarkers using a consolidated workflow from total nucleic acids, which can be isolated using dedicated sample isolation protocols that have been developed specifically for the QIAseq Multimodal Panels.
From DNA:
- Single nucleotide variants (SNVs)
- Insertions and Deletions (InDels)
- Copy number variants (CNVs)
From RNA:
- Fusions
- Exon skipping events
- Gene expression levels
Product Resources
Customers who bought these products also bought
- Cat No./ID:333602
QIAseq Targeted RNAscan Panel (12)
Kit containing ALL reagents (except indexes) for targeted Fusion sequencing; fixed panel for 12 samples; less than 100 fusionsSelect Targets - Cat No./ID:74004
RNeasy Micro Kit (50)
50 RNeasy MinElute Spin Columns, Collection Tubes (1.5ml and 2ml), RNase-free DNase I, Carrier RNA, RNase-free Reagents and Buffers$522.00Add To Cart - Cat No./ID:333505
QIAseq Targeted DNA Panel (96)
Kit containing ALL reagents (except indexes) for targeted DNA sequencing; fixed panel for 96 samples; less than 100 genesSelect Targets - Cat No./ID:333802
QIAseq Targeted DNA IO Panel (12)
Kit containing ALL reagents (except indexes) for targeted DNA sequencing; fixed panel for 12 samples; more than 100 genesSelect Targets - Cat No./ID:333414
QIAseq DNA QuantiMIZE Assay Kit
Assay 100 and Assay 200 for 400 x 25µl reactions (400µl) each; QuantiMIZE Control gDNA (50µl); RNase- and DNase-free water (1 ml x 4); GeneRead qPCR SYBR Green Mastermix (1.35 ml x 4)
Select Targets - Cat No./ID:333714
QIAseq 12-Index I (48)
Box containing combinatorial dual-indexed adapters, for indexing up to 12 samples for QIAseq Targeted Panel sequencing on Illumina platforms; enough to process a total of 48 samples
$1,176.00Add To Cart - Cat No./ID:80234
AllPrep DNA/RNA FFPE Kit (50)
50 RNeasy MinElute Spin Columns, 50 QIAamp MinElute Spin Columns, Collection Tubes, RNase-Free Reagents, and Buffers$700.00Add To Cart - Cat No./ID:333314
QIAseq Library Quant Assay Kit
1 tube of Primer Mix (500 µl), 1 bottle of Dilution Buffer (30 ml), 1 tube DNA Standard (100 µl), and 5 tubes GeneRead qPCR SYBR Green (1.35 ml) for sample library quantification prior to NGSSelect Targets - Cat No./ID:28706X4
QIAquick Gel Extraction Kit (1000)
For gel extraction or cleanup of 1000 reactions: 1000 QIAquick Spin Columns, Buffers, Collection Tubes (2 ml)$1,879.00Add To Cart - Cat No./ID:19093
Deparaffinization Solution (16 ml)
2 x 8 ml Deparaffinization Solution$191.00Add To Cart - Cat No./ID:180134
GeneRead DNA FFPE Kit
For 50 preps: QIAamp MinElute Columns, Collection Tubes, Deparaffinization Solution, Uracil-N-Glycosylase, RNase-Free Water, RNase A, and Buffers$328.00Add To Cart - Cat No./ID:203205
HotStarTaq DNA Polymerase (1000 U)
4 x 250 units HotStarTaq DNA Polymerase, 10x PCR Buffer, 5x Q-Solution, 25 mM MgCl2$538.00Add To Cart - Cat No./ID:28115
QIAquick Spin Columns (100)
For DNA fragment purification from PCR, gel fragments and enzymatic reactions$125.00Add To Cart - Cat No./ID:19086
Buffer EB (250 ml)
250 ml Elution Buffer$36.10Add To Cart - Cat No./ID:972804
PyroMark Gold Q96 Reagents (5 x 96)
For performing Pyrosequencing reactions on the PyroMark Q96 ID (5 x 96) and PyroMark Q96 MD (15 x 96)$601.00Add To Cart - Cat No./ID:74106
RNeasy Mini Kit (250)
250 RNeasy Mini Spin Columns, Collection Tubes (1.5 ml and 2 ml), RNase-free Reagents and Buffers$1,451.00Add To Cart