QIAseq Library Quant System
- Ready-to-use, predispensed, sequentially diluted DNA standard (array format)
- Automatic calculation of library concentration
- Simple protocol, high sensitivity, and wide dynamic range
- Compatibility with Illumina andIon Torrent/ProtonNGS platforms
- Compatibility with most qPCR instruments
The QIAseq Library Quant System provides a simple, out-of-the-box solution to quantify NGS libraries, enabling consistent results with every NGS run. The QIAseq Library Quant System uses real-time PCR to specifically quantify DNA molecules with sequencing adaptors at both ends, ensuring optimal cluster density or template-to-bead ratio.
Please note:GeneRead Library Quant Array (product number 180611) andGeneRead Library Quant Kit (product number 180612) will be phased out by the end of 2016. Please useQIAseq Library Quant Assay Kit (product number333314) instead.
Need a quote for your research project or would you like to discuss your project with our specialist team? Contact Us
- Buy Products
- Product Details
Buy Products
Cat No./ID:333304 GeneRead Library Quant Array Go to GeneGlobePCR arrays with accessory components for sample library quantification prior to next-generation sequencing |
Cat No./ID:333314 QIAseq Library Quant Assay Kit $428.00 1 tube of Primer Mix (500 µl), 1 bottle of Dilution Buffer (30 ml), 1 tube DNA Standard (100 µl), and 5 tubes GeneRead qPCR SYBR Green (1.35 ml) for sample library quantification prior to NGS |
Product Details
The sensitivity and dynamic range of the QIAseq Library Quant System were compared against Agilent"s High Sensitivity DNA Kit, using two NGS libraries of differing concentrations. The first library was quantifiable by both systems, but the low concentration of the second library was below the detection limit of Agilent"s 2100 BioAnalyzer. By contrast, the QIAseq Library Quant Array was able to quantify both libraries (see figure QIAseq Library Quant System enables quantification of libraries with concentrations below the detection limit of conventional methods).
The array format workflow (see figure QIAseq Library QuantArrayworkflow) begins with two tenfold dilutions of the sample library, to ensure that its concentration falls within the range of the serially diluted standards. The samples are mixed with QIAseq qPCR SYBR Green Mastermix and aliquoted in technical triplicate across the array plate. PCR is performed, and raw CT values are exported to the provided data analysis Excel file for automatic calculation of library concentration (Illumina platform) or template dilution factor (Ion Torrent/Proton platform).
The tube format workflow is similar to the array format workflow, with a few small differences. The procedure begins with preparation of five sequential tenfold dilutions of DNA Standard and two tenfold dilutions of the sample library. This ensures that the concentration of the library will fall within the range of the standard dilutions. Next, the diluted DNA standards and sample libraries are mixed with the provided PCR assay and the appropriate QIAseq qPCR SYBR Green Mastermix. PCR is performed, and CT values are exported to the provided data analysis Excel file for automatic calculation of library concentration (Illumina platform) or template dilution factor (Ion Torrent/Proton platform).
Product Resources
Customers who bought these products also bought
- Cat No./ID:333602
QIAseq Targeted RNAscan Panel (12)
Kit containing ALL reagents (except indexes) for targeted Fusion sequencing; fixed panel for 12 samples; less than 100 fusionsSelect Targets - Cat No./ID:333074
QIAseq UPX 3" Trans. 12-Index (48)
For indexing up to 12 samples per sequencing lane on Illumina NGS instruments; multiple 96- or 384-well plates can be combined as one sample allowing for 12 x 96-well plates (1152 cells/wells) or 12 x 384-well plates (4608 cells/wells) per lane$1,033.00Add To Cart - Cat No./ID:333088
QIAseq UPX 3" Transcriptome Kit (96)
For 3" gene expression analysis from cells or mRNA of 8–96 samples at one time; each kit contains cell lysis solution, buffers, oligos and enzymes lyophilized in a 96-well plate which can be easily separated for processing 8–96 samples in parallel (this format is ideal for both small and large sample sizes)$2,959.00Add To Cart - Cat No./ID:333515
QIAseq Targeted DNA HC Panel (96)
Kit containing ALL reagents (except indexes) for targeted DNA sequencing; fixed panel for 96 samples; more than 100 genesSelect Targets - Cat No./ID:333414
QIAseq DNA QuantiMIZE Assay Kit
Assay 100 and Assay 200 for 400 x 25µl reactions (400µl) each; QuantiMIZE Control gDNA (50µl); RNase- and DNase-free water (1 ml x 4); GeneRead qPCR SYBR Green Mastermix (1.35 ml x 4)
Select Targets - Cat No./ID:333512
QIAseq Targeted DNA HC Panel (12)
Kit containing ALL reagents (except indexes) for targeted DNA sequencing; fixed panel for 12 samples; more than 100 genesSelect Targets - Cat No./ID:180986
GeneRead Adapter I Set B 12-plex (144)
For 144 reactions: 12 barcoded adapters for ligation to DNA library, for use with Illumina instruments$1,250.00Add To Cart - Cat No./ID:333505
QIAseq Targeted DNA Panel (96)
Kit containing ALL reagents (except indexes) for targeted DNA sequencing; fixed panel for 96 samples; less than 100 genesSelect Targets - Cat No./ID:333090
QIAseq UPX 3" Transcriptome Kit (384)
For 3" gene expression analysis from cells or mRNA of 384 samples simultaneously; each kit contains cell lysis solution, buffers, oligos and enzymeslyophilized on a 384-well plate for processing 384 samples in parallel (this format is best suited for large samples numbers of at least 384 samples)$8,996.00Add To Cart - Cat No./ID:333502
QIAseq Targeted DNA Panel (12)
Kit containing ALL reagents (except indexes) for targeted DNA sequencing; fixed panel for 12 samples; less than 100 genesSelect Targets - Cat No./ID:180434
GeneRead DNA Library I Core Kit (48)
For48 reactions: Buffers and reagents for end-repair, A-Addition, and ligation, for use with Illumina instruments$1,083.00Add To Cart - Cat No./ID:333714
QIAseq 12-Index I (48)
Box containing combinatorial dual-indexed adapters, for indexing up to 12 samples for QIAseq Targeted Panel sequencing on Illumina platforms; enough to process a total of 48 samples
$1,176.00Add To Cart - Cat No./ID:32903
C-Terminus pQE Vector Set
25 µg each: pQE-16, pQE-60, pQE-70$699.00Add To Cart - Cat No./ID:52304
QIAamp RNA Blood Mini Kit (50)
For 50 RNA preps: 50 QIAamp Mini Spin Columns, 50 QIAshredder Spin Columns, Collection Tubes (1.5 ml and 2 ml), RNase-free reagents and buffers$385.00Add To Cart - Cat No./ID:180455
GeneRead DNA I Amp Kit (100)
For 100 reactions: Ready-to-use library amplification master mix and primer mix, for use with Illumina instruments$364.00Add To Cart - Cat No./ID:333727
QIAseq 96-Index I Set A (384)
Box containing combinatorial dual-indexed adapters, for indexing up to 96 samples for QIAseq Targeted Panel sequencing on Illumina platforms; enough to process a total of 384 samples; 1st of 4 sets required for multiplexing 384 samples
$5,183.00Add To Cart - Cat No./ID:929002
QIAxcel DNA High Resolution Kit (1200)
QIAxcel DNA High Resolution Gel Cartridge, Buffers, Mineral Oil, QX Intensity Calibration Marker, 12-Tube Strips$1,079.00Add To Cart - Cat No./ID:180473
QIAseq FX DNA Library Kit (24)
Buffers and reagents for DNA fragmentation (including end repair and A-addition), ligation and library amplification; for use with Illumina instruments; includes a plate containing 24 combinatorial dual index adapters with different bar codes (pierceable foil seal, allowing usage of defined parts of plate)
$864.00Add To Cart - Cat No./ID:981103
Strip Tubes and Caps, 0.1 ml (250)
250 strips of 4 tubes and caps for 1000 reactions of 10–50 µl$250.00Add To Cart - Cat No./ID:180715
QIAseq FX Single Cell DNA Library Kit (96)
For 96 reactions: Buffers and reagents for cell lysis, whole genome amplification and library preparation including DNA fragmentation, end-repair and adapter ligation. Includes a plate containing 96 barcoded adapters for use with Illumina instruments.
$3,984.00Add To Cart