
QIAseq Ultralow Input Library Kit
- Ultra-efficient chemistries maximize performance of sub-nanogram samples
- Flexible protocol provides a comprehensive solution for 10 pg−100 ng DNA input
- Automation-friendly, dual-barcoded adapter plate included in 96-reaction kit
- Compatible with a wide range of sample types, including cfDNA, FFPE, ancient DNA and ChIP-seq
The QIAseq Ultralow Input Library Kit incorporates new, ultra-efficient end-repair and ligation chemistries into a complete and streamlined solution. These kits allow the generation of high-quality libraries from limited and damaged DNA sample types using a streamlined, 2.5-hour workflow – starting from10 pg –100 ng fragmented DNA for a robust solution suitable for a wide range of research applications.
Need a quote for your research project or would you like to discuss your project with our specialist team? Contact Us
- Buy Products
- Product Details
Buy Products
Cat No./ID:180492 QIAseq Ultralow Input Library Kit (12) $331.00 For 12 reactions: buffers and reagents for Ultralow Input End Polishing, Ultralow Input Ligation and HiFi library amplification. 12-plex adapters sold separately. For use with Illumina instruments. |
Cat No./ID:180495 QIAseq Ultralow Input Library Kit (96) $3,050.00 For 96 reactions: buffers and reagents for Ultralow Input End Polishing, Ultralow Input Ligation and HiFi library amplification. Includes 96-plex Adapter Plate with individually pierceable foil sealed wells. For use with Illumina instruments. |
Product Details
Maximum yield from minimal input
Confidently process samples from 10 pg to 100 ng DNA input.The new, highly efficient chemistries in QIAseq Ultralow Input Kits eliminate the issue of performance drop-off below 1 ng of input DNA. Novel enzymes and buffer formulations maximize the performance of sub-nanogram samples while also enabling the flexibility to process samples with up to 100 ng input DNA.
Highly efficient and consistent conversion rates
QIAseq Ultralow Input Library Kits enable superior library conversion rates (>30%) from samples below 1 ng of input using newly optimized chemistry formulations. These consistent conversion rates of genomic information to adapter-ligated library molecules cover a 1000-fold range – from 10 pg to 10 ng of DNA input – and set an industry-leading benchmark. The low percentage of adapter dimers minimizes library contamination compared to the competition.
Robust solution for challenging samples
QIAseq Ultralow Input chemistry is ideal for: low-input whole genome sequencing; cfDNA for liquid biopsy applications; and limited sources of DNA from FFPE tissue, laser capture microdissection (LCM) and fine needle aspirations (FNA).
Next-generation sequencing (NGS) is a driving force for many new and exciting applications, including cancer research, stem cell research, metagenomics, population genetics and medical research. While NGS technology is continuously improving, library preparation remains a process bottleneck for many labs and a limiting factor in the types of samples that can successfully generate NGS data.
As a result, capturing the maximum possible genomic information in an NGS library is both critical and challenging, when starting from limited or damaged DNA samples. Standard library preparation methods that apply to many sample types – such as circulating cell-free DNA, FFPE DNA, ancient DNA and ChIP-seq DNA – can result in quality-related problems. These problems limit the utility of the data generated, from low library yield or conversion rates to high percentages of reads derived from adapter dimer molecules.
Library construction
QIAseq Ultralow Input Library Kits start with double-stranded DNA that has been fragmented enzymatically, chemically, mechanically or naturally. Kits use an optimized end-polishing reaction and a new Ultralow Input Ligation formulation, along with QIAGEN’s proprietary HiFi PCR Master Mix. This combination maximizes the conversion rate of sample DNA into the NGS library, while efficiently and evenly amplifying even high and low GC content regions of the genome. This protocol enables the highest possible yield sequencing library, free of adapter dimer contamination – starting from a little as 10−100 pg* of DNA input. Due to the kit’s flexible protocol, the same kit can also be used for higher DNA input amounts, including PCR-free library preparations from as little as 10 pg or as high as 100 ng of DNA input. *Note that the genomic complexity necessary for a given experiment will vary depending on the genome size of the organism and the fraction of that genome included in the target region of interest.Reaction cleanup
Following adapter ligation and library amplification steps, reaction cleanup and removal of residual adapter dimers can be achieved by using Agencourt AMPure XP beads – which enable easy automation on various high throughput automation platforms.Optional amplification of library DNA
PCR-based library amplification is normally required if the input DNA amount is below 100 ng. This protocol is optional, and enables high-fidelity amplification of the DNA library using the QIAseq HiFi PCR Master Mix that is included in the kit.
Contents and accessories
Dual-barcoded, plate-format adapters are included with the 96-reaction size QIAseq Ultralow Input Library Kit. Each well in the 96-plex adapter plate contains a single-use adapter consisting of a unique combination of two eight-nucleotide identification barcodes. By combining one i5 barcode and one i7 barcode in each ready-to-use adapter, the 96 reaction QIAseq Ultralow Input Kits supports up to 96-plex pooling of libraries prior to sequencing.While adapters are not included in the 12-reaction size kit, two sets of 12-plex adapters with a single six-nucleotide barcode can each be ordered separately (QIAGEN cat. nos. 180985, 180986).
QIAGEN QIAseq Ultralow Input Library Kits have been designed to be the definitive solution for generating high quality libraries from even very challenging NGS samples. Intended for NGS researchers who seek a single library prep kit compatible with a wide range of ultra-low, low and standard input fragmented DNA – QIAseq Ultralow Input Library Kits enable new insights by maximizing performance, particularly from limited and damaged DNA sample types. The streamlined, 2.5-hour protocol for generating libraries from fragmented DNA using QIAseq Ultralow Input Library Kits also enables straightforward automation on different liquid-handling platforms.
Product Resources
Customers who bought these products also bought
- Cat No./ID:180015
QIAseq cfDNA Library Kit (96)
For 96 reactions on Illumina® sequencers: enzymes and buffers for cfDNA library prep, Illumina Adapter Plate 96-plex, Illumina Library Amplification Primer and PCR Master Mix$3,050.00Add To Cart - Cat No./ID:180985
GeneRead Adapter I Set A 12-plex (144)
For 144 reactions: 12 barcoded adapters for ligation to DNA library, for use with Illumina instruments$1,283.00Add To Cart - Cat No./ID:180986
GeneRead Adapter I Set B 12-plex (144)
For 144 reactions: 12 barcoded adapters for ligation to DNA library, for use with Illumina instruments$1,250.00Add To Cart - Cat No./ID:180773
QIAseq Stranded mRNA Select Kit (24)
For mRNA enrichment and strand-specific RNA-seq library preparation of 24 samples: Kits include magnetized reaction cleanup beads and sample index adapters for Illumina NGS platforms
$1,247.00Add To Cart - Cat No./ID:180477
QIAseq FX DNA Library UDI Kit (24)
Buffers and reagents for DNA fragmentation (including end repair and A-addition), ligation and library amplification; for use with Illumina instruments; includes a plate containing 24 Unique Dual Index Y-adapters.
$907.00Add To Cart - Cat No./ID:301005
Attractene Transfection Reagent (1 ml)
Attractene Transfection Reagent for up to 660 transfections in 24-well plates$422.00Add To Cart - Cat No./ID:34650
RGS·His Antibody, BSA-free (100 μg)
100 μg mouse anti·RGS(H)4 (lyophilized, BSA-free, for 1000ml working solution)$742.00Add To Cart - Cat No./ID:76064
exoEasy Maxi Kit (20)
For 20 vesicle preps: 20 exoEasy Maxi Spin Columns, Collection Tubes (50 ml), Reagents and Buffers$739.00Add To Cart - Cat No./ID:382617
Investigator 26plex QS Kit (400)
Primer Mix, Fast Reaction Mix 3.0includingTaqDNA Polymerase, Control DNA, allelic ladder 26plex, and nuclease-free water
$8,908.00Add To Cart - Cat No./ID:13323
Blood & Cell Culture DNA Mini Kit (25)
25 QIAGEN Genomic-tip 20/G, QIAGEN Protease, Buffers$300.00Add To Cart - Cat No./ID:386125
Matrix Standard BT5 multi cap. (50)
Matrix standard for 6-FAM, BTG, BTY, BTR, and BTO, for multi-capillary analyzers$109.00Add To Cart - Cat No./ID:219610
miRNeasy Serum/Plasma Spike-In Control
10 pmol lyophilized C. elegans miR-39 miRNA mimic$51.30Add To Cart - Cat No./ID:386224
Matrix Standard BT6 (50)
Matrix standard for 6-FAM, BTG, BTY, BTR2, BTP, and BTO, for Applied Biosystems 3500 Genetic Analyzers$175.00Add To Cart - Cat No./ID:51331
QIAamp 96 DNA QIAcube HT Kit (5)
For 480 preps: QIAamp 96 plates, QIAGEN Proteinase K, buffers$791.00Add To Cart - Cat No./ID:301705
HiPerFect Transfection Reagent (1 ml)
HiPerFect Transfection Reagent for up to 333 transfections in 24-well plates or up to 1333 transfections in 96-well plates$404.00Add To Cart - Cat No./ID:387416
Investigator Quantiplex Pro Calibration Kit
For use on Applied Biosystems 7500 Real-Time Systems: Calibration Standard FAM (60 µl), Calibration Standard JOE (60 µl), Calibration Standard ATTO 550 (60 µl), Calibration Standard ROX (60 µl), Calibration Standard ATTO 647N (60 µl), Quantiplex Pro Calibration Buffer (30 ml)
$332.00Add To Cart - Cat No./ID:30230
Ni-NTA Agarose (100 ml)
100 ml nickel-charged resin (max. pressure: 2.8 psi)$1,114.00Add To Cart - Cat No./ID:330701
RT2 lncRNA qPCR Assay
For 200 reactions; mix of 2 gene-specific primers provided in solution (200 µl), with 10 µM of each primerSelect Targets - Cat No./ID:57731
QIAamp 96 Virus QIAcube HT Kit (5)
For 480 preps: QIAamp 96 plates, QIAGEN Proteinase K, carrier RNA, buffers$1,553.00Add To Cart - Cat No./ID:180475
QIAseq FX DNA Library Kit (96)
Buffers and reagents for DNA fragmentation (including end repair and A-addition), ligation and library amplification; for use with Illumina instruments; includes a plate containing 96 combinatorial dual index adapters with different bar codes (pierceable foil seal, allowing usage of defined parts of plate)
$3,423.00Add To Cart