4000-520-616
欢迎来到免疫在线!(蚂蚁淘生物旗下平台)  请登录 |  免费注册 |  询价篮
主营:主营:分子类化合物
咨询热线电话
4000-520-616
当前位置: 首页 > 产品中心 > peptide > Qiagen/QIAseq FastSelect –rRNA HMR Kits/Includes 3 tubes of QIAseq FastSelect reagent for globin mRNA removal; sufficient for 24 reactions from human, mouse and rat samples/334376
商品详细Qiagen/QIAseq FastSelect –rRNA HMR Kits/Includes 3 tubes of QIAseq FastSelect reagent for globin mRNA removal; sufficient for 24 reactions from human, mouse and rat samples/334376
Qiagen/QIAseq FastSelect –rRNA HMR Kits/Includes 3 tubes of QIAseq FastSelect reagent for globin mRNA removal; sufficient for 24 reactions from human, mouse and rat samples/334376
Qiagen/QIAseq FastSelect –rRNA HMR Kits/Includes 3 tubes of QIAseq FastSelect reagent for globin mRNA removal; sufficient for 24 reactions from human, mouse and rat samples/334376
商品编号: 334376
品牌: Qiagen
市场价: ¥21600.00
美元价: 12960.00
产地: 美国(厂家直采)
公司:
产品分类: 多肽合成
公司分类: peptide
联系Q Q: 3392242852
电话号码: 4000-520-616
电子邮箱: info@ebiomall.com
商品介绍

QIAseq FastSelect –rRNA HMR Kits

Product picture
For rapid rRNA and/or globin mRNAremoval for RNA-seq library preparation from human, mouse, rat and other mammalian samples
  • Compatible with QIAGEN, Illumina, NEB and KAPA stranded RNA-seq library kits
  • Single reagent for human, mouse, rat and other mammalian species
  • High-performance rRNA and/or globin removal in just 14 minutes
  • Only one pipetting step – combine QIAseq FastSelect reagent with RNA and incubate
  • No extra cleanup steps or NGS library protocol changes

QIAseq FastSelect –rRNA HMR and QIAseq FastSelect –Globin Kits use a novel method to remove highly abundant RNA that is of low scientific value from your RNA-seq libraries. Researchers using RNA-seq for whole transcriptome analysis can use QIAseq FastSelect –rRNA HMR to remove cytoplasmic and mitochondrial rRNA, while researchers starting with blood samples can use QIAseq FastSelect –rRNA/Globin to remove both rRNA and globin mRNA. For researchers who are enriching for mRNA from blood, and only want to remove globin mRNA, we recommend QIAseq FastSelect –Globin. QIAseq FastSelect –rRNA HMR and QIAseq FastSelect –Globin Kits remove more unwanted RNA and are 30% faster than our previous kit versions.

We recommend usingQIAseq Stranded RNA Library Kitsfor robust strand-specific RNA-seq library preparation for high-quality and highly fragmented (FFPE) RNA.

Interested in customization of a QIAseq FastSelect –rRNA HMR or QIAseq FastSelect –Globin Kit for your samples?Contact us!

Want to try theQIAseq FastSelect –rRNA/Globin Kitfor the first time? Request a trial kit to evaluate.

  • Buy Products
  • Product Details
  • Product Resources

Buy Products

Cat No./ID:334376
QIAseq FastSelect –Globin Kit (24)
$1,080.00
Order Product

Includes3 tubes of QIAseq FastSelect reagent forglobin mRNAremoval; sufficient for24reactions from human, mouse and rat samples

Cat No./ID:334377
QIAseq FastSelect –Globin Kit (96)
$3,890.00
Order Product

Includes1 tube of QIAseq FastSelect reagent forglobin mRNAremoval; sufficient for96reactions from human, mouse and rat samples

Cat No./ID:334378
QIAseq FastSelect –Globin Kit (384)
$14,999.00
Order Product

Includes 4 tubes of QIAseq FastSelect reagent forglobin mRNAremoval; sufficient for 384reactions from human, mouse and rat samples

Cat No./ID:334386
QIAseq FastSelect–rRNA HMR Kit (24)
$1,080.00
Order Product

Includes3 tubes of QIAseq FastSelect reagent for rRNA removal; sufficient for24reactions from human, mouse and rat samples

Cat No./ID:334387
QIAseq FastSelect –rRNA HMR Kit (96)
$3,890.00
Order Product

Includes1 tube of QIAseq FastSelect reagent for rRNA removal; sufficient for96reactions from human, mouse and rat samples

Cat No./ID:334388
QIAseq FastSelect –rRNA HMR Kit (384)
$14,999.00
Order Product

Includes 4 tubes of QIAseq FastSelect reagent for rRNA removal; sufficient for 384reactions from human, mouse and rat samples

Cat No./ID:335376
QIAseq FastSelect –rRNA/Globin Kit (24)
$1,989.00
Order Product

Includes3 tubes of QIAseq FastSelect reagent for rRNA removal and3 tubes of QIAseq FastSelect reagent for globin mRNA removal; sufficient for24 reactions from human, mouse and rat samples

Cat No./ID:335377
QIAseq FastSelect –rRNA/Globin Kit (96)
$7,499.00
Order Product

Includes1 tube of QIAseq FastSelect reagent for rRNA removal and1 tube of QIAseq FastSelect reagent for globin mRNA removal; sufficient for96 reactions from human, mouse and rat samples

Cat No./ID:335378
QIAseq FastSelect –rRNA/Globin Kit (384)
$24,999.00
Order Product

Includes 4 tubes of QIAseq FastSelect reagent for rRNA removal and 4 tubes of QIAseq FastSelect reagent for globin mRNA removal; sufficient for 384 reactions from human, mouse and rat samples

QIAseq FastSelect –rRNA HMR Kits are intended for molecular biology applications. These products are not intended for the diagnosis, prevention, or treatment of a disease.

Product Details

9

QIAseq FastSelect –rRNA/Globin Kit shows consistent results over a broad range of RNA input: highly efficient and reproducible removal of rRNA and globin mRNA, regardless of RNA input

Stranded transcriptome libraries were prepared from 100 ng and 1 µg aliquots of human blood total RNA using the QIAseq FastSelect –rRNA/Globin Kit and QIAseq Stranded Total RNA Lib Kit.To remove rRNA and globin mRNA during the QIAseq library prep, QIAseq FastSelect –rRNA HMR + –Globin was combined with each RNA sample and 5x RT Buffer. The samples were then heated (fragmented) at 95°C for 15 min and stepwise cooled to 25°C over 14 minutes. The remaining library prep steps were then performed according to the QIAseq Stranded Total RNA Lib Kit instructions. Sequencing was performed on a NextSeq 550 and data analysis was performed using CLC Biomedical Workbench. The percent or reads mapping to rRNA and globin is shown.
9

QIAseq FastSelect Kit workflow

Simply add QIAseq FastSelect reagent (rRNA Removal and/or Globin Removal) to your RNA sample, perform fragmentation (if required), then initiate a stepwise cool-down from 75°C to 25°C over 14 minutes. Researchers can then complete the remaining library preparation steps without any additional changes to their workflow. QIAseq FastSelect works with or without RNA fragmentation, providing the flexibility to use FFPE or degraded RNA samples, or high-quality RNA as part of a standard RNA-seq library construction workflow.QIAseq FastSelect –rRNA HMR Kits, QIAseq FastSelect –Globin Kits, QIAseq FastSelect –rRNA/Globin Kit, QIAseq FastSelect –rRNA Plant Kits and QIAseq FastSelect –rRNA Yeast Kits have been tested with the QIAseq Stranded Total RNA Lib Kit (QIAGEN), TruSeq Stranded (Illumina), NEBNext Ultra II Directional (New England Biolabs) and KAPA RNA HyperPrep (KAPA Biosystems) library preparation kits.
9

QIAseq FastSelect –rRNA HMR Kit is a single solution that removes mitochondrial and cytoplasmic rRNA from human, mouse, rat and other mammalian samples

QIAseq FastSelect –rRNA HMR Kit removes more than 95% of the rRNA from human, mouse, rat, horse, cow, hamster and sheep samples and >80% removal for dog, monkey, chicken, rabbit and pig samples.
9

QIAseq FastSelect –rRNA HMR Kit has comprehensive coverage to remove cytoplasmic and mitochondrial rRNA targets

QIAseq FastSelect –rRNA HMR was designed to remove both cytoplasmic (5S, 5.8S, 18S, 28S) and mitochondrial (12S, 16S) rRNA for human, mouse and rat samples.
9

QIAseq FastSelect –Globin Kit has comprehensive coverage to remove adult, fetal and embryonic globin mRNA

QIAseq FastSelect –Globin was designed to remove adult, fetal and embryonic globin mRNA from human, mouse and rat samples.
9

QIAseq FastSelect –rRNA HMR Kit provides greater rRNA removal than previous kit versions

QIAseq FastSelect –rRNA HMR is a new formulation of QIAseq FastSelect which provides a single-tube solution for human, mouse and rat samples. The new formulation shows an increased potency in removing rRNA with highly reproducible results. The improved QIAseq FastSelect –rRNA HMR Kit exhibits greater rRNA removal than kit previous versions.
9

QIAseq FastSelect –rRNA HMR Kit shows comparable gene expression results with previous kit versions

QIAseq FastSelect –rRNA HMR Kit is a single-tube solution for human, mouse, rat and other mammalian samples. Gene expression data from human, mouse and rat universal RNA samples was compared using QIAseq FastSelect –rRNA HMR Kit and the previous versions of the kit. This data shows that the single-tube QIAseq FastSelect –rRNA HMR Kit can replace previous versions of QIAseq FastSelect RNA Removal Kits, which used species-specific human, mouse and rat solutions.
9

QIAseq FastSelect –rRNA HMR Kit provides consistent distribution of read mapping between replicates

To test the reproducibility of the QIAseq FastSelect –rRNA HMR Kit and QIAseq Stranded Total RNA Lib Kit,100 ng of human universal RNA (HURR) was used in duplicate. Following RNA-seq library preparation and sequencing, the data was aligned using CLC Genomics Workbench. Mapped read percentages were highly reproducible, with 49% mapping to exons, 45% mapping to introns and 5% mapping to intergenic regions. Only 1.2% of the reads mapped to rRNA following treatment – a reduction of >95%.
9

QIAseq FastSelect –rRNA HMR Kit maintains the expression profile: detection of expressed genes (RPKM >0.3)

To test the reproducibility of the QIAseq FastSelect –rRNA HMR Kit and QIAseq Stranded Total RNA Lib Kit, 100 ng of human universal RNA (HURR) was used in duplicate. Following RNA-seq library preparation and sequencing, the data was aligned using CLC Genomics Workbench. An average of 14,929 genes were detected with an RPKM >0.3.
9

QIAseq FastSelect–rRNA HMR Kit maintains the expression profile: consistent detection of expressed genes (RPKM >0.3)

To test the reproducibility of the QIAseq FastSelect –rRNA HMR Kit and QIAseq Stranded Total RNA Lib Kit, 100 ng of human universal RNA (HURR) was used in duplicate. Following RNA-seq library preparation and sequencing, the data was aligned using CLC Genomics Workbench. Expressed genes with an RPKM >0.3 were compared between the 2 replicates resulting in a high degree of concordance.
9

QIAseq FastSelect –rRNA/Globin Kit shows consistent results over a broad range of RNA input: highly consistent breakdown of mapped reads, regardless of RNA input

Stranded transcriptome libraries were prepared from 100 ng and 1 µg aliquots of human blood total RNA using the QIAseq FastSelect –rRNA/Globin Kit and QIAseq Stranded Total RNA Lib Kit.To remove rRNA and globin mRNA during the QIAseq library prep, QIAseq FastSelect –rRNA HMR + –Globin was combined with each RNA sample and 5x RT Buffer. The samples were then heated (fragmented) at 95°C for 15 min and stepwise cooled to 25°C over14 minutes. The remaining library prep steps were then performed according to the QIAseq Stranded Total RNA Lib Kit instructions. Sequencing was performed on a NextSeq 550 and data analysis was performed using CLC Biomedical Workbench. Mapped read percentages were highly reproducible with 35% mapping to exon, 58% mapping to introns and 5% mapping to intergenic regions. Only 1–2% of the reads mapped to rRNA and less than 1% mapped to globin transcripts.
9

QIAseq FastSelect –rRNA/Globin Kit shows consistent results over a broad range of RNA input: gene expression results

Stranded transcriptome libraries were prepared from 100 ng and 1 µg aliquots of human blood total RNA using the QIAseq FastSelect –rRNA/Globin Kit and QIAseq Stranded Total RNA Lib Kit.To remove rRNA and globin mRNA during the QIAseq library prep, QIAseq FastSelect –rRNA HMR + –Globin was combined with each RNA sample and 5x RT Buffer. The samples were then heated (fragmented) at 95°C for 15 min and stepwise cooled to 25°C over 14 minutes. The remaining library prep steps were then performed according to the QIAseq Stranded Total RNA Lib Kit instructions. Sequencing was performed on a NextSeq 550 and data analysis was performed using CLC Biomedical Workbench. Gene expression results for 100 ng and 1 µg of RNA, for genes with an RPKM >0.3, show a high degree of correlation.
9

QIAseq FastSelect –rRNA HMR works with FFPE and degraded RNA samples

QIAseq FastSelect –rRNA HMR Kit removes rRNA from FFPE RNA fusion gene reference samples.FFPE RNA reference standards A FFPE Horizon 5-Fusion Multiplex Positive and B FFPE Horizon 5-Fusion Multiplex Negative Control were used to prepare duplicate RNA-seq libraries using QIAseq FastSelect –rRNA HMR and QIAseq Stranded Total RNA Lib Kits. QIAseq FastSelect consistently removed >95% of the rRNA from the sample even though the input RNA was highly fragmented.
9

QIAseq FastSelect –rRNA HMR works with FFPE and degraded RNA samples: removal of rRNA leads to increased exon mapping

QIAseq FastSelect –rRNA HMR Kit removes rRNA from FFPE RNA fusion gene reference samples.FFPE RNA reference standards A FFPE Horizon 5-Fusion Multiplex Positive and B FFPE Horizon 5-Fusion Multiplex Negative Control were used to prepare duplicate RNA-seq libraries using QIAseq FastSelect –rRNA HMR and QIAseq Stranded Total RNA Lib Kits. Removal of rRNA leads to an increase in exon mapping. FFPE Horizon 5-Fusion Multiplex Positive and Negative Control samples show an exon mapping rate of approximately 40% versus 10% in the untreated samples.
9

QIAseq FastSelect –rRNA HMR works with FFPE and degraded RNA samples: gene expression results

QIAseq FastSelect –rRNA HMR Kit removes rRNA from FFPE RNA fusion gene reference samples.When rRNA depletion is performed using QIAseq FastSelect (Log2 normalized gene expression, targets with RPKM >0.3), gene expression results are highly reproducible.
9

QIAseq FastSelect –rRNA HMR: robust performance with FFPE RNA samples

QIAseq FastSelect –rRNA HRM removes rRNA from FFPE RNA samplesA QIAseq FastSelect results in highly efficient removal of rRNA from fragmented samples. The percentage of reads mapped to rRNA is shown. B Exon/intron/intergenic read mapping is shown. QIAseq FastSelect results in a substantial increase in the percentage of reads mapped to exonic regions.
9

QIAseq FastSelect –rRNA HMR: robust performance with FFPE RNA samples: gene expression results

QIAseq FastSelect –rRNA HRM removes rRNA from FFPE RNA samples.When rRNA depletion is performed using QIAseq FastSelect (Log2 normalized gene expression, targets with RPKM >0.3), QIAseq FastSelect treatment vs. no treatment results suggest that QIAseq FastSelect does not perturb the natural expression profile of samples.
9

QIAseq FastSelect –rRNA HMR Kit removes rRNA with 1 step in 14 minutes

QIAseq FastSelect –rRNA HMR is a new formulation that works to remove mitochondrial and cytoplasmic rRNA from human, mouse, rat and other mammalian samples. QIAseq FastSelect HMR shows greater potency than QIAGEN’s species-specific formulations currently on the market.A QIAseq FastSelect –rRNA HMR Kit works to remove unwanted RNAs from your RNA-seq library using 1 step. This is significantly easier than hybridization or RNase H methods, which require 29 to 37 steps (e.g., Supplier I, Supplier N and Supplier T).B QIAseq FastSelect –rRNA HMR Kit works in only 14 minutes, which saves hours versus other methods, and is 30% faster than existing QIAseq FastSelect RNA Removal Kits.
Performance

QIAseq FastSelect –rRNA HMR Kits demonstrated highly efficient removal of rRNA and superior performance compared to our previous kit versions and alternative products.See figures:QIAseq FastSelect –rRNA HMR Kit removes rRNA with 1 step in 14 minutesQIAseq FastSelect –rRNA HMR Kit has comprehensive coverage to remove cytoplasmic and mitochondrial rRNA targetsQIAseq FastSelect –Globin Kit has comprehensive coverage to remove adult, fetal and embryonic globin mRNA RNAQIAseq FastSelect –rRNA HMR Kit provides greater rRNA removal than previous kit versionsQIAseq FastSelect –rRNA HMR Kit shows comparable gene expression results with previous kit versionsQIAseq FastSelect –rRNA HMR Kit maintains the expression profile: detection of expressed genes (RPKM >0.3)QIAseq FastSelect–rRNA HMR Kit maintains the expression profile: consistent detection of expressed genes (RPKM >0.3)

Robust performance with a variety of sample types, regardless of RNA input

QIAseq FastSelect provides reliable rRNA removal, consistent read mapping and reproducible gene expression results with RNA extracted from various sample types, including FFPE, and over a broad range of RNA input amounts.See figures:QIAseq FastSelect –rRNA HMR Kit is a single solution that removes mitochondrial and cytoplasmic rRNA from human, mouse, rat and other mammalian samplesQIAseq FastSelect –rRNA HMR Kit provides consistent distribution of read mapping between replicatesQIAseq FastSelect –rRNA/Globin Kit shows consistent results over a broad range of RNA input: highly efficient and reproducible removal of rRNA and globin mRNA, regardless of RNA inputQIAseq FastSelect –rRNA/Globin Kit shows consistent results over a broad range of RNA input: highly consistent breakdown of mapped reads, regardless of RNA inputQIAseq FastSelect –rRNA/Globin Kit shows consistent results over a broad range of RNA input: gene expression resultsQIAseq FastSelect –rRNA HMR works with FFPE and degraded RNA samplesQIAseq FastSelect –rRNA HMR works with FFPE and degraded RNA samples: removal of rRNA leads to increased exon mappingQIAseq FastSelect –rRNA HMR works with FFPE and degraded RNA samples: gene expression resultsQIAseq FastSelect –rRNA HMR: robust performance with FFPE RNA samplesQIAseq FastSelect –rRNA HMR: robust performance with FFPE RNA samples: gene expression results

Principle

Removing highly expressed, but biologically unimportant RNA transcripts makes NGS more efficient and enables higher sample throughput with higher sensitivity. Furthermore, removal of unwanted RNA species from FFPE samples and from degraded RNA samples is particularly challenging and can result in suboptimal performance.

QIAseq FastSelect is designed for quick, efficient removal of cytoplasmic and mitochondrial rRNA and/or globin mRNA from total RNA during NGS RNA library preparation. QIAseq FastSelect seamlessly integrates with your existing RNA stranded library preparation workflow for RNA removal in a single, 14-minute inline step. Prior to RNA heat fragmentation (which is optional and dependent upon the library preparation kit and sample type), QIAseq FastSelect removal reagent is directly combined with total RNA and the library preparation-specific buffers. After fragmentation, the reaction temperature is stepwise cooled to room temperature and the remaining library preparation steps are completed. There is no need to perform any type of enrichment on the total RNA samples. QIAseq FastSelect –rRNA HMR and QIAseq FastSelect –Globin Kits ensure consistently high performance with RNA amounts ranging from as little as 1 ng to 1 µg. QIAseq FastSelect can be used with RNA from fresh samples, as well as RNA from FFPE (formalin-fixed paraffin-embedded) samples or degraded RNA, and delivers reliable rRNA removal and high reproducibility in downstream applications.

Procedure

Most RNA removal or depletion strategies associated with RNA-seq library construction are sample pre-treatment strategies involving hybrid-capture or enzymatic removal of unwanted RNA. Our unique QIAseq FastSelect procedure is compatible with QIAGEN, Illumina, KAPA and NEB stranded library preparation kits and provides complete rRNA removal in a single, 14-minute inline step (figure QIAseq FastSelect Kit workflow). This is dramatically faster than alternative RNA depletion kits, which require pre-treatment protocols involving more than 25 steps and 2 hours to complete.

Simply add QIAseq FastSelect reagent (rRNA Removal and/or Globin Removal) to the RNA sample, perform fragmentation (if required), stepwise cool the reaction from 75°C to 25°C for 14 minutes and then complete the remaining library preparation steps. QIAseq FastSelect works with or without RNA fragmentation, providing the flexibility to use RNA from FFPE samples or degraded RNA samples, or high-quality RNA as part of a standard RNA-seq library construction workflow.

Applications

QIAseq FastSelect delivers rapid, reliable RNA removal from FFPE and fresh sample RNA sources. QIAseq FastSelect –rRNA HMR and QIAseq FastSelect –Globin Kits are available in a variety of different formats and sizes to suit your specific applications.

Product Resources

You are not authorized to download the resource

Brochures & Guides (2)
  • Sort options
    • Sort alphabetically
QIAseq FastSelect –rRNA and Globin HMR Kits – interactive product profile
Show details
The underestimated role of rRNA removal from FFPE and liquid biopsy samples
Presentation describing the underestimated role of rRNA removal from FFPE and liquid biopsy samples
Show details
Kit Handbooks (1)
  • Sort options
    • Sort alphabetically
QIAseq FastSelect −rRNA HMR and −Globin Handbook
Show details
Supplementary Protocols (1)
  • Sort options
    • Sort alphabetically
QIAseq FastSelect −rRNA HMR and/or −Globin with the Truseq Stranded Total RNA Library Prep
Show details
Quick-Start Protocols (8)
  • Sort options
    • Sort alphabetically
QIAseq FastSelect −Globin with the KAPA mRNA HyperPrep Kit
Show details
QIAseq FastSelect −rRNA HMR and/or −Globin with the KAPA RNA HyperPrep Kit
Show details
QIAseq FastSelect −Globin with the NEBNext Poly(A) mRNA Magnetic Isolation Module & Ultra II Directional Library Prep Kit
Show details
QIAseq FastSelect −rRNA HMR and/or −Globin with the NEBNext Ultra II Directional Library Prep Kit
Show details
QIAseq FastSelect −Globin with the QIAseq Stranded mRNA Select Kit
Show details
QIAseq FastSelect −rRNA HMR and/or −Globin with the QIAseq Stranded Total RNA Lib Kit
Show details
QIAseq FastSelect −Globin with the TruSeq Stranded mRNA Library Prep
Show details
QIAseq FastSelect −rRNA HMR and/or −Globin with TruSeq Stranded Library Preparation
Show details
Safety Data Sheets (10)
  • Sort options
    • Sort alphabetically
MSDS QIAseq FastSelect –rRNA HMR Kit (24)
MSDS QIAseq FastSelect –rRNA HMR Kit (96)
MSDS QIAseq FastSelect –rRNA HMR Kit (384)
MSDS QIAseq FastSelect –Globin Kit (24)
MSDS QIAseq FastSelect –Globin Kit (96)
MSDS QIAseq FastSelect –Globin Kit (384)
MSDS QIAseq FastSelect –rRNA/Globin Kit (24)
MSDS QIAseq FastSelect –rRNA/Globin Kit (96)
MSDS QIAseq FastSelect –rRNA/Globin Kit (384)
MSDS QIAseq FastSelect –rRNA HMRKit (8)
fragment fix placeholder

Customers who bought these products also bought

  • Cat No./ID:180775
    /us/products//discovery-and-translational-research/next-generation-sequencing/whole-genome-transcriptome-amplification/whole-transcriptome/qiaseq-stranded-rna-library-kits/

    QIAseq Stranded mRNA Select Kit (96)

    For mRNA enrichment and strand-specific RNA-seq library preparation of 96 samples: Kits include magnetized reaction cleanup beads and sample index adapters for Illumina NGS platforms

    $4,124.00
    Add To Cart
  • Cat No./ID:335925
    /us/products//discovery-and-translational-research/next-generation-sequencing/rna-sequencing/ribosomal-rna-and-globin-mrna-removal/qiaseq-fastselect-5s-16s-23s-kits/

    QIAseq FastSelect –5S/16S/23S Kit (24)

    Includes 3 tubes of QIAseq FastSelect –5S/16S/23S rRNA removal reagent, reaction buffer, QIAseq Beads with QIAseq bead binding buffer and nuclease-free water sufficient for 24 samples

    $1,299.00
    Add To Cart
  • Cat No./ID:335927
    /us/products//discovery-and-translational-research/next-generation-sequencing/rna-sequencing/ribosomal-rna-and-globin-mrna-removal/qiaseq-fastselect-5s-16s-23s-kits/

    QIAseq FastSelect –5S/16S/23S Kit (96)

    Includes 1 tube of QIAseq FastSelect –5S/16S/23S rRNA removal reagent, reaction buffer, QIAseq Beads with QIAseq bead binding buffer and nuclease-free water sufficient for 96 samples

    $4,499.00
    Add To Cart
  • Cat No./ID:180743
    /us/products//discovery-and-translational-research/next-generation-sequencing/whole-genome-transcriptome-amplification/whole-transcriptome/qiaseq-stranded-rna-library-kits/

    QIAseq Stranded Total RNA Lib Kit (24)

    For strand-specific RNA-seq library preparation of 24 samples: Kits include magnetized reaction cleanup beads and sample index adapters for Illumina NGS platforms
    $1,178.00
    Add To Cart
  • Cat No./ID:180745
    /us/products//discovery-and-translational-research/next-generation-sequencing/whole-genome-transcriptome-amplification/whole-transcriptome/qiaseq-stranded-rna-library-kits/

    QIAseq Stranded Total RNA Lib Kit (96)

    For strand-specific RNA-seq library preparation of 96 samples: Kits include magnetized reaction cleanup beads and sample index adapters for Illumina NGS platforms
    $3,967.00
    Add To Cart
  • Cat No./ID:12145X4
    /us/products//discovery-and-translational-research/dna-rna-purification/dna-purification/plasmid-dna/qiagen-plasmid-kits/

    QIAGEN Plasmid Midi Kit (400)

    400 QIAGEN-tip 100, Reagents, Buffers
    $3,626.00
    Add To Cart
  • Cat No./ID:180773
    /us/products//discovery-and-translational-research/next-generation-sequencing/whole-genome-transcriptome-amplification/whole-transcriptome/qiaseq-stranded-rna-library-kits/

    QIAseq Stranded mRNA Select Kit (24)

    For mRNA enrichment and strand-specific RNA-seq library preparation of 24 samples: Kits include magnetized reaction cleanup beads and sample index adapters for Illumina NGS platforms

    $1,247.00
    Add To Cart
  • Cat No./ID:929562
    /us/products//instruments-and-automation/quality-control-fragment-analysis/qiaxcel-dna-accessories/

    QX DNA Size Marker 250bp–4kb (50ul) v2.0

    DNA size marker with fragments of 250, 500, 750, 1000, 1200, 1500, 2000, 2500, 3000, 3500, and 4000 bp; concentration 100 ng/ul
    $81.30
    Add To Cart
  • Cat No./ID:338114
    /us/products//discovery-and-translational-research/pcr-qpcr-dpcr/qpcr-assays-and-instruments/mrna-incrna-qpcr-assays-panels/xpressref-universal-total-rna/

    Mouse XpressRef Universal Total RNA

    2 tubes each containing 100 μg Mouse XpressRef Universal Total RNA
    $317.00
    Add To Cart
  • Cat No./ID:12863
    /us/products//discovery-and-translational-research/dna-rna-purification/dna-purification/plasmid-dna/compactprep-plasmid-maxi-kits/

    CompactPrep Plasmid Maxi Kit (25)

    25 CompactPrep Maxi Columns, Extender tubes, Reagents, Buffers, LyseBlue
    $584.00
    Add To Cart
  • Cat No./ID:13116-400
    /us/products//instruments-and-automation/accessories/bulk-beads/

    Glass Beads, 0.5 mm (400 g)

    Customize your bead tubes with bulk beads for rapid and reliable biological sample lysis from a wide variety of starting materials.
    $264.00
    Add To Cart
  • Cat No./ID:929526
    /us/products//instruments-and-automation/quality-control-fragment-analysis/qiaxcel-dna-accessories/

    QX Alignment Marker 50 bp/1 kb (1.5 ml)

    Alignment marker with 50 bp and 1 kb fragments
    $96.60
    Add To Cart
  • Cat No./ID:331565
    /us/products//discovery-and-translational-research/next-generation-sequencing/metagenomics/qiaseq-mirna-ngs/

    QIAseq miRNA NGS 96 Index IL (96)

    Sequencing adapters, primers and indices compatible with Illumina platforms; 96 indices for 96 samples (pre-plated in 96-well plate for ease of use)
    $1,113.00
    Add To Cart
  • Cat No./ID:19301
    /us/products//discovery-and-translational-research/lab-essentials/plastics/powerbead-tubes/

    PowerBead Pro Tubes (2 ml) (50)

    Bead tubes ready for rapid and reliable biological sample lysis from a wide variety of starting materials, 2 ml
    $196.00
    Add To Cart
  • Cat No./ID:929529
    /us/products//instruments-and-automation/quality-control-fragment-analysis/qiaxcel-dna-accessories/

    QX Alignment Marker 50 bp/5 kb (1.5 ml)

    Alignment marker with 50 bp and 5 kb fragments
    $97.00
    Add To Cart
  • Cat No./ID:331505
    /us/products//discovery-and-translational-research/next-generation-sequencing/metagenomics/qiaseq-mirna-ngs/

    QIAseq miRNALibrary Kit (96)

    For 96 sequencing prep reactions: 3’ ligation, 5’ ligation, reverse-transcription, cDNA cleanup, library amplification and library cleanup reagents; quality control primers
    $7,014.00
    Add To Cart
  • Cat No./ID:37612
    /us/products//discovery-and-translational-research/protein-purification/fractionation-and-depletion/qproteome-mitochondria-isolation-kit/

    Qproteome Mitochondria Isolation Kit

    Buffers and reagents for 12 high-purity mitochondrial preparations
    $383.00
    Add To Cart
  • Cat No./ID:74034
    /us/products//diagnostics-and-clinical-research/sample-processing/rneasy-plus-micro-and-mini-kits/

    RNeasy Plus Micro Kit (50)

    For 50 micropreps: RNeasy MinElute Spin Columns, gDNA Eliminator Spin Columns, Collection Tubes, Carrier RNA, RNase-Free Water and Buffers
    $462.00
    Add To Cart
  • Cat No./ID:334215
    /us/products//discovery-and-translational-research/next-generation-sequencing/rna-sequencing/ribosomal-rna-and-globin-mrna-removal/qiaseq-fastselect-rrna-yeast-kits/

    QIAseq FastSelect –rRNA Yeast Kit (24)

    Includes 3 tubes of QIAseq FastSelect reagent for cytoplasmic and mitochondrial rRNA removal; sufficient for 24 reactions from yeast samples

    $1,080.00
    Add To Cart
  • Cat No./ID:207045
    /us/products//discovery-and-translational-research/pcr-qpcr-dpcr/real-time-pcr-enzymes-and-kits/reverse-transcription-cdna-synthesis-qpcr/quantitect-whole-transcriptome-kit/

    QuantiTect Whole Transcriptome Kit (100)

    For 100 x 50 µl reactions: 100 µl T-Script Enzyme, 400 µl T-Script Buffer, 100 µl Ligation Enzyme 1, 100 µl Ligation Enzyme 2, 200 µl Ligation Reagent, 600 µl Ligation Buffer, 100 µl REPLI-g Midi DNA Polymerase, 2 x 1.45 ml REPLI-g Midi Reaction Buffer
    $3,269.00
    Add To Cart
品牌介绍
QIAGEN是一家专业化致力于生物分子样品制备解决方案的跨国经营企业,总部位于德国。1984年,QIAGEN在德国成立,1996年在美国纽约纳斯达克上市。QIAGEN拥有超过1000项专利和认可证明,在18个国家设立了分公司,代理商服务国超过40个,在全球有超过400000的用户。QIAGEN提供的产品超过500类,包括各种试剂,耗材和自动化纯化工作站。这些产品用于样品采集,稳定,核酸或蛋白的分离,纯化和检测中,不仅广泛的应用于科研领域的各个方面,在生物技术,制药,法医研究,食品安全检测,畜牧业和分子诊断领域也得到了广泛的应用。QIAGEN产品的卓越品质和在应用中的出色表现使得其成为样品处理中标准的代名词。