
QIAseq FastSelect –rRNA HMR Kits
- Compatible with QIAGEN, Illumina, NEB and KAPA stranded RNA-seq library kits
- Single reagent for human, mouse, rat and other mammalian species
- High-performance rRNA and/or globin removal in just 14 minutes
- Only one pipetting step – combine QIAseq FastSelect reagent with RNA and incubate
- No extra cleanup steps or NGS library protocol changes
QIAseq FastSelect –rRNA HMR and QIAseq FastSelect –Globin Kits use a novel method to remove highly abundant RNA that is of low scientific value from your RNA-seq libraries. Researchers using RNA-seq for whole transcriptome analysis can use QIAseq FastSelect –rRNA HMR to remove cytoplasmic and mitochondrial rRNA, while researchers starting with blood samples can use QIAseq FastSelect –rRNA/Globin to remove both rRNA and globin mRNA. For researchers who are enriching for mRNA from blood, and only want to remove globin mRNA, we recommend QIAseq FastSelect –Globin. QIAseq FastSelect –rRNA HMR and QIAseq FastSelect –Globin Kits remove more unwanted RNA and are 30% faster than our previous kit versions.
We recommend usingQIAseq Stranded RNA Library Kitsfor robust strand-specific RNA-seq library preparation for high-quality and highly fragmented (FFPE) RNA.
Interested in customization of a QIAseq FastSelect –rRNA HMR or QIAseq FastSelect –Globin Kit for your samples?Contact us!
Want to try theQIAseq FastSelect –rRNA/Globin Kitfor the first time? Request a trial kit to evaluate.
- Buy Products
- Product Details
Buy Products
Cat No./ID:334376 QIAseq FastSelect –Globin Kit (24) $1,080.00 Includes3 tubes of QIAseq FastSelect reagent forglobin mRNAremoval; sufficient for24reactions from human, mouse and rat samples |
Cat No./ID:334377 QIAseq FastSelect –Globin Kit (96) $3,890.00 Includes1 tube of QIAseq FastSelect reagent forglobin mRNAremoval; sufficient for96reactions from human, mouse and rat samples |
Cat No./ID:334378 QIAseq FastSelect –Globin Kit (384) $14,999.00 Includes 4 tubes of QIAseq FastSelect reagent forglobin mRNAremoval; sufficient for 384reactions from human, mouse and rat samples |
Cat No./ID:334386 QIAseq FastSelect–rRNA HMR Kit (24) $1,080.00 Includes3 tubes of QIAseq FastSelect reagent for rRNA removal; sufficient for24reactions from human, mouse and rat samples |
Cat No./ID:334387 QIAseq FastSelect –rRNA HMR Kit (96) $3,890.00 Includes1 tube of QIAseq FastSelect reagent for rRNA removal; sufficient for96reactions from human, mouse and rat samples |
Cat No./ID:334388 QIAseq FastSelect –rRNA HMR Kit (384) $14,999.00 Includes 4 tubes of QIAseq FastSelect reagent for rRNA removal; sufficient for 384reactions from human, mouse and rat samples |
Cat No./ID:335376 QIAseq FastSelect –rRNA/Globin Kit (24) $1,989.00 Includes3 tubes of QIAseq FastSelect reagent for rRNA removal and3 tubes of QIAseq FastSelect reagent for globin mRNA removal; sufficient for24 reactions from human, mouse and rat samples |
Cat No./ID:335377 QIAseq FastSelect –rRNA/Globin Kit (96) $7,499.00 Includes1 tube of QIAseq FastSelect reagent for rRNA removal and1 tube of QIAseq FastSelect reagent for globin mRNA removal; sufficient for96 reactions from human, mouse and rat samples |
Cat No./ID:335378 QIAseq FastSelect –rRNA/Globin Kit (384) $24,999.00 Includes 4 tubes of QIAseq FastSelect reagent for rRNA removal and 4 tubes of QIAseq FastSelect reagent for globin mRNA removal; sufficient for 384 reactions from human, mouse and rat samples |
Product Details
QIAseq FastSelect –rRNA HMR Kits demonstrated highly efficient removal of rRNA and superior performance compared to our previous kit versions and alternative products.See figures:QIAseq FastSelect –rRNA HMR Kit removes rRNA with 1 step in 14 minutesQIAseq FastSelect –rRNA HMR Kit has comprehensive coverage to remove cytoplasmic and mitochondrial rRNA targetsQIAseq FastSelect –Globin Kit has comprehensive coverage to remove adult, fetal and embryonic globin mRNA RNAQIAseq FastSelect –rRNA HMR Kit provides greater rRNA removal than previous kit versionsQIAseq FastSelect –rRNA HMR Kit shows comparable gene expression results with previous kit versionsQIAseq FastSelect –rRNA HMR Kit maintains the expression profile: detection of expressed genes (RPKM >0.3)QIAseq FastSelect–rRNA HMR Kit maintains the expression profile: consistent detection of expressed genes (RPKM >0.3)
Robust performance with a variety of sample types, regardless of RNA input
QIAseq FastSelect provides reliable rRNA removal, consistent read mapping and reproducible gene expression results with RNA extracted from various sample types, including FFPE, and over a broad range of RNA input amounts.See figures:QIAseq FastSelect –rRNA HMR Kit is a single solution that removes mitochondrial and cytoplasmic rRNA from human, mouse, rat and other mammalian samplesQIAseq FastSelect –rRNA HMR Kit provides consistent distribution of read mapping between replicatesQIAseq FastSelect –rRNA/Globin Kit shows consistent results over a broad range of RNA input: highly efficient and reproducible removal of rRNA and globin mRNA, regardless of RNA inputQIAseq FastSelect –rRNA/Globin Kit shows consistent results over a broad range of RNA input: highly consistent breakdown of mapped reads, regardless of RNA inputQIAseq FastSelect –rRNA/Globin Kit shows consistent results over a broad range of RNA input: gene expression resultsQIAseq FastSelect –rRNA HMR works with FFPE and degraded RNA samplesQIAseq FastSelect –rRNA HMR works with FFPE and degraded RNA samples: removal of rRNA leads to increased exon mappingQIAseq FastSelect –rRNA HMR works with FFPE and degraded RNA samples: gene expression resultsQIAseq FastSelect –rRNA HMR: robust performance with FFPE RNA samplesQIAseq FastSelect –rRNA HMR: robust performance with FFPE RNA samples: gene expression results
Removing highly expressed, but biologically unimportant RNA transcripts makes NGS more efficient and enables higher sample throughput with higher sensitivity. Furthermore, removal of unwanted RNA species from FFPE samples and from degraded RNA samples is particularly challenging and can result in suboptimal performance.
QIAseq FastSelect is designed for quick, efficient removal of cytoplasmic and mitochondrial rRNA and/or globin mRNA from total RNA during NGS RNA library preparation. QIAseq FastSelect seamlessly integrates with your existing RNA stranded library preparation workflow for RNA removal in a single, 14-minute inline step. Prior to RNA heat fragmentation (which is optional and dependent upon the library preparation kit and sample type), QIAseq FastSelect removal reagent is directly combined with total RNA and the library preparation-specific buffers. After fragmentation, the reaction temperature is stepwise cooled to room temperature and the remaining library preparation steps are completed. There is no need to perform any type of enrichment on the total RNA samples. QIAseq FastSelect –rRNA HMR and QIAseq FastSelect –Globin Kits ensure consistently high performance with RNA amounts ranging from as little as 1 ng to 1 µg. QIAseq FastSelect can be used with RNA from fresh samples, as well as RNA from FFPE (formalin-fixed paraffin-embedded) samples or degraded RNA, and delivers reliable rRNA removal and high reproducibility in downstream applications.
Most RNA removal or depletion strategies associated with RNA-seq library construction are sample pre-treatment strategies involving hybrid-capture or enzymatic removal of unwanted RNA. Our unique QIAseq FastSelect procedure is compatible with QIAGEN, Illumina, KAPA and NEB stranded library preparation kits and provides complete rRNA removal in a single, 14-minute inline step (figure QIAseq FastSelect Kit workflow). This is dramatically faster than alternative RNA depletion kits, which require pre-treatment protocols involving more than 25 steps and 2 hours to complete.
Simply add QIAseq FastSelect reagent (rRNA Removal and/or Globin Removal) to the RNA sample, perform fragmentation (if required), stepwise cool the reaction from 75°C to 25°C for 14 minutes and then complete the remaining library preparation steps. QIAseq FastSelect works with or without RNA fragmentation, providing the flexibility to use RNA from FFPE samples or degraded RNA samples, or high-quality RNA as part of a standard RNA-seq library construction workflow.
QIAseq FastSelect delivers rapid, reliable RNA removal from FFPE and fresh sample RNA sources. QIAseq FastSelect –rRNA HMR and QIAseq FastSelect –Globin Kits are available in a variety of different formats and sizes to suit your specific applications.
Product Resources
Customers who bought these products also bought
- Cat No./ID:180775
QIAseq Stranded mRNA Select Kit (96)
For mRNA enrichment and strand-specific RNA-seq library preparation of 96 samples: Kits include magnetized reaction cleanup beads and sample index adapters for Illumina NGS platforms
$4,124.00Add To Cart - Cat No./ID:335925
QIAseq FastSelect –5S/16S/23S Kit (24)
Includes 3 tubes of QIAseq FastSelect –5S/16S/23S rRNA removal reagent, reaction buffer, QIAseq Beads with QIAseq bead binding buffer and nuclease-free water sufficient for 24 samples
$1,299.00Add To Cart - Cat No./ID:335927
QIAseq FastSelect –5S/16S/23S Kit (96)
Includes 1 tube of QIAseq FastSelect –5S/16S/23S rRNA removal reagent, reaction buffer, QIAseq Beads with QIAseq bead binding buffer and nuclease-free water sufficient for 96 samples
$4,499.00Add To Cart - Cat No./ID:180743
QIAseq Stranded Total RNA Lib Kit (24)
For strand-specific RNA-seq library preparation of 24 samples: Kits include magnetized reaction cleanup beads and sample index adapters for Illumina NGS platforms$1,178.00Add To Cart - Cat No./ID:180745
QIAseq Stranded Total RNA Lib Kit (96)
For strand-specific RNA-seq library preparation of 96 samples: Kits include magnetized reaction cleanup beads and sample index adapters for Illumina NGS platforms$3,967.00Add To Cart - Cat No./ID:12145X4
QIAGEN Plasmid Midi Kit (400)
400 QIAGEN-tip 100, Reagents, Buffers$3,626.00Add To Cart - Cat No./ID:180773
QIAseq Stranded mRNA Select Kit (24)
For mRNA enrichment and strand-specific RNA-seq library preparation of 24 samples: Kits include magnetized reaction cleanup beads and sample index adapters for Illumina NGS platforms
$1,247.00Add To Cart - Cat No./ID:929562
QX DNA Size Marker 250bp–4kb (50ul) v2.0
DNA size marker with fragments of 250, 500, 750, 1000, 1200, 1500, 2000, 2500, 3000, 3500, and 4000 bp; concentration 100 ng/ul$81.30Add To Cart - Cat No./ID:338114
Mouse XpressRef Universal Total RNA
2 tubes each containing 100 μg Mouse XpressRef Universal Total RNA$317.00Add To Cart - Cat No./ID:12863
CompactPrep Plasmid Maxi Kit (25)
25 CompactPrep Maxi Columns, Extender tubes, Reagents, Buffers, LyseBlue$584.00Add To Cart - Cat No./ID:13116-400
Glass Beads, 0.5 mm (400 g)
Customize your bead tubes with bulk beads for rapid and reliable biological sample lysis from a wide variety of starting materials.$264.00Add To Cart - Cat No./ID:929526
QX Alignment Marker 50 bp/1 kb (1.5 ml)
Alignment marker with 50 bp and 1 kb fragments$96.60Add To Cart - Cat No./ID:331565
QIAseq miRNA NGS 96 Index IL (96)
Sequencing adapters, primers and indices compatible with Illumina platforms; 96 indices for 96 samples (pre-plated in 96-well plate for ease of use)$1,113.00Add To Cart - Cat No./ID:19301
PowerBead Pro Tubes (2 ml) (50)
Bead tubes ready for rapid and reliable biological sample lysis from a wide variety of starting materials, 2 ml$196.00Add To Cart - Cat No./ID:929529
QX Alignment Marker 50 bp/5 kb (1.5 ml)
Alignment marker with 50 bp and 5 kb fragments$97.00Add To Cart - Cat No./ID:331505
QIAseq miRNALibrary Kit (96)
For 96 sequencing prep reactions: 3’ ligation, 5’ ligation, reverse-transcription, cDNA cleanup, library amplification and library cleanup reagents; quality control primers$7,014.00Add To Cart - Cat No./ID:37612
Qproteome Mitochondria Isolation Kit
Buffers and reagents for 12 high-purity mitochondrial preparations$383.00Add To Cart - Cat No./ID:74034
RNeasy Plus Micro Kit (50)
For 50 micropreps: RNeasy MinElute Spin Columns, gDNA Eliminator Spin Columns, Collection Tubes, Carrier RNA, RNase-Free Water and Buffers$462.00Add To Cart - Cat No./ID:334215
QIAseq FastSelect –rRNA Yeast Kit (24)
Includes 3 tubes of QIAseq FastSelect reagent for cytoplasmic and mitochondrial rRNA removal; sufficient for 24 reactions from yeast samples
$1,080.00Add To Cart - Cat No./ID:207045
QuantiTect Whole Transcriptome Kit (100)
For 100 x 50 µl reactions: 100 µl T-Script Enzyme, 400 µl T-Script Buffer, 100 µl Ligation Enzyme 1, 100 µl Ligation Enzyme 2, 200 µl Ligation Reagent, 600 µl Ligation Buffer, 100 µl REPLI-g Midi DNA Polymerase, 2 x 1.45 ml REPLI-g Midi Reaction Buffer$3,269.00Add To Cart