QIAseq Targeted RNAscan Panels
- Accurate quantification of a large number of fusion genes
- Identify new fusion gene partners, no prior knowledge of breakpoint needed
- Works with low-quality RNA, including RNA from FFPE and liquid biopsy
- Requires low RNA input, as low as 15 ng of un-enriched RNA
- Automation-friendly
The QIAseq Targeted RNAscan Panels are a complete Sample to Insight solution that applies the molecular barcode-based digital RNA sequencing strategy to quantify known and new fusion genes. Digital RNA sequencing is a unique approach in which genes are tagged with molecular barcodes before amplification, overcoming the issues of PCR duplicates and library bias. In addition, the unique single primer extension approach allows the detection of new fusion gene partners. The proprietary data-analysis pipeline enables highly confident calls of low-abundance fusion transcripts and novel fusion gene identification.
Each QIAseq Targeted RNAscan Panel contains all the necessary components to construct libraries from enriched targets. The panels are platform-agnostic and will work on both Illumina and Ion Torrent instruments. The primer design is based on single primer extension, in which each target is enriched by one target-specific primer and one universal primer – a strategy that reduces the amount of required primers. All primers required for a panel are pooled into an individual primer pool to reduce panel handling and the number of pools required for enrichment and library construction. Platform-specific indexes, which are contained in a separate box, allow multiplexing of up to 384 samples per sequencing run.
- Buy Products
- Product Details
Buy Products
Cat No./ID:333602 QIAseq Targeted RNAscan Panel (12) $1,297.00 Kit containing ALL reagents (except indexes) for targeted Fusion sequencing; fixed panel for 12 samples; less than 100 fusions |
Cat No./ID:333605 QIAseq Targeted RNAscan Panel (96) $7,559.00 Kit containing ALL reagents (except indexes) for targeted Fusion sequencing; fixed panel for 96 samples; less than 100 fusions |
Cat No./ID:333612 QIAseq Targeted RNAscan HC Panel (12) $1,944.00 Kit containing ALL reagents (except indexes) for targeted Fusion sequencing; fixed panel for 12 samples; more than 100 fusions |
Cat No./ID:333615 QIAseq Targeted RNAscan HC Panel (96) $10,799.00 Kit containing ALL reagents (except indexes) for targeted Fusion sequencing; fixed panel for 96 samples; more than 100 fusions |
Product Details
- Accuracy: Innovative digital sequencing (incorporating molecular barcodes) eliminates PCR duplication and amplification bias to confidently detect known and novel fusions.
- Specificity: The unique combination of our proprietary primer design algorithm and rigorous testing of every primer assay guarantees high specificity and accurate results.
- Content: The QIAseq targeted RNAscan panels offer a high degree of flexibility in content and sample multiplexing. Several cataloged panels have been developed for a wide range of applications. One can also build a custom panel for specific content, or to extend the contents of an existing cataloged panel. Up to 384 samples can be multiplexed using the QIAseq indexes.
- Flexibility: Because the QIAseq targeted RNAscan panels use single primer extension, primers can be designed to detect known fusions based on characterized breakpoints or to discover novel fusions.
The QIAseq Targeted RNAscan Panels can be used to detect known and novel gene fusions from a wide range of sample types for numerous applications.
Sample types:
- FFPE
- Fresh or frozen tissue
- Cell lines
Applications:
- Detection of known gene fusions based on well-characterized breakpoints
- Discovery of novel gene fusions using exon- or gene-based primer designs
Product Resources
Customers who bought these products also bought
- Cat No./ID:333764
QIAseq 12-Index L (48)
Box containing oligos for indexing up to 12 samples for QIAseq Targeted Panel sequencing on Ion Torrent platforms; enough to process a total of 48 samples
$1,176.00Add To Cart - Cat No./ID:333714
QIAseq 12-Index I (48)
Box containing combinatorial dual-indexed adapters, for indexing up to 12 samples for QIAseq Targeted Panel sequencing on Illumina platforms; enough to process a total of 48 samples
$1,176.00Add To Cart - Cat No./ID:333802
QIAseq Targeted DNA IO Panel (12)
Kit containing ALL reagents (except indexes) for targeted DNA sequencing; fixed panel for 12 samples; more than 100 genesSelect Targets - Cat No./ID:333512
QIAseq Targeted DNA HC Panel (12)
Kit containing ALL reagents (except indexes) for targeted DNA sequencing; fixed panel for 12 samples; more than 100 genesSelect Targets - Cat No./ID:12997-50
DNeasy PowerClean Pro Cleanup Kit (50)
For the removal of PCR inhibitors from purified DNA in just 7 minutes$241.00Add To Cart - Cat No./ID:333932
QIAseq Multimodal Panel (12)
Kit containing ALL reagents (except indices) sufficient to process 12 samples for multimodal (DNA and RNA) sequencing; fixed small panel for a total of 24 reactions
Select Targets - Cat No./ID:333505
QIAseq Targeted DNA Panel (96)
Kit containing ALL reagents (except indexes) for targeted DNA sequencing; fixed panel for 96 samples; less than 100 genesSelect Targets - Cat No./ID:339306
miRCURY LNA miRNA PCR Assay
Contains forward and reverse primers for 200 reactions; for SYBR® Green-based detection
Select Targets - Cat No./ID:333962
QIAseq Multimodal Index I (12)
Box containing indices, enough to process a total of 12 samples, for indexing up to a total of 12 samples for QIAseq Multimodal Panel sequencing on Illumina platforms
$800.00Add To Cart - Cat No./ID:333502
QIAseq Targeted DNA Panel (12)
Kit containing ALL reagents (except indexes) for targeted DNA sequencing; fixed panel for 12 samples; less than 100 genesSelect Targets - Cat No./ID:333074
QIAseq UPX 3" Trans. 12-Index (48)
For indexing up to 12 samples per sequencing lane on Illumina NGS instruments; multiple 96- or 384-well plates can be combined as one sample allowing for 12 x 96-well plates (1152 cells/wells) or 12 x 384-well plates (4608 cells/wells) per lane$1,033.00Add To Cart - Cat No./ID:333727
QIAseq 96-Index I Set A (384)
Box containing combinatorial dual-indexed adapters, for indexing up to 96 samples for QIAseq Targeted Panel sequencing on Illumina platforms; enough to process a total of 384 samples; 1st of 4 sets required for multiplexing 384 samples
$5,183.00Add To Cart - Cat No./ID:990394
Rotor Adapters (10 x 24)
For 240 preps: 240 Disposable Rotor Adapters and 240 Elution Tubes (1.5 ml); for use with the QIAcube$45.60Add To Cart