
QIAseq SARS-CoV-2 Primer Panel
- High-fidelity reagents for reverse transcription and enrichment of SARS-CoV-2 RNA
- When paired with a QIAseq FX DNA Library Unique Dual Index (UDI) Kit, multiplex 384 samples in a single run
- Fast 3–3.5 hour enrichment workflow with limited hands-on time
The QIAseq SARS-CoV-2 Primer Panel is specially designed to advance research into SARS-CoV-2, which is the causative agent of COVID-19 disease. This kit, when paired with a QIAseq FX DNA Library UDI Kit, is a solution for enriching and sequencing the entire viral genome. SARS-CoV-2 is encoded by a positive-sense, single-stranded RNA molecule that can be mixed with host RNA during isolation from a sample. The kit includes reagents to reverse transcribe the RNA into cDNA and primers to specifically enrich for its genome. The panel consists of over 200 primer pairs, covering the full 29.9 kb viral genome.
Want to try the QIAseq SARS-CoV-2 Primer Panel for the first time? Request a quote for a trial kit.
Want to try the QIAseq FX DNA Library UDI Kit for the first time? Request a quote for a trial kit.
- Buy Products
- Product Details
Buy Products
Cat No./ID:333895 QIAseq SARS-CoV-2 Primer Panel (24) $260.00 Reagents and primers for reverse transcription, whole genome amplification and downstream Illumina sequencing; for 24 reactions |
Cat No./ID:333896 QIAseq SARS-CoV-2 Primer Panel (96) $960.00 Reagents and primers for reverse transcription, whole genome amplification and downstream Illumina sequencing; for 96 reactions |
Product Details
High-quality, single-box solution
Targeting SARS-CoV-2 requires both reverse transcription and whole genome enrichment of the viral RNA. The QIAseq SARS-CoV-2 Primer Panel combines both of these steps to generate amplicons for downstream library creation. When paired with a QIAseq FX DNA Library UDI Kit, you can construct sequencing-ready libraries compatible with Illumina platforms.
Community primer design
QIAseq SARS-CoV-2 primer pools utilize designs from the ARTIC V3 primers. The primers have also gone through an in silico check to reduce chances for dimerization during sample enrichment.
Multiplexing
Combine with a QIAseq FX DNA Library UDI Kit to enable multiplexing on high-throughput Illumina instruments, such as the NovaSeq (up to 384 samples per flow cell).
Data analysis
When paired with QIAGEN CLC Genomics Workbench, the panel can deliver data that can be quickly analyzed. Sequence data can be used to identify variants across different samples, as well as compare it to multiple genomes – from consensus reference genomes to one of many genomes that have been uploaded from around the world.
Viruses consist of nucleic acid (viral genome) and a limited number of proteins that facilitate entry into the host cell, replication of the genome and production of virions. While viral genomes can be comprised of RNA or DNA, SARS-CoV-2 is encoded by an RNA molecule. The size of the entire SARS-CoV-2 genome is under 30 kb and can be mixed with host RNA when isolating from a human sample, making it challenging to reconstruct the whole genome of the virus.
While next-generation sequencing (NGS) has become a vital tool, library preparation remains a key bottleneck in the NGS workflow. The QIAseq SARS-CoV-2 Primer Panel is a multiplex PCR primer set for whole genome amplification of SARS-CoV-2. Using primer pools that utilize designs from ARTIC V3 primers, the QIAseq SARS-CoV-2 Primer Panel generates amplicons that cover the entire SARS-CoV-2 genome. Combine with a QIAseq FX DNA Library UDI Kit to convert the amplicons into NGS-ready fragments compatible with lllumina sequencers.
From cDNA synthesis to enrichment
The QIAseq SARS-CoV-2 Primer Panel workflow begins with converting total viral RNA into cDNA using random priming (no rRNA depletion or poly-A selection is required). This reaction is flexible with regards to input RNA used for the reverse transcription reaction. To elaborate, 5 µl viral RNA input is required as a starting point. When the viral RNA has been previously assessed using a qPCR assay, the CT value should be between 18–35. If the CT is between 12–15, then dilute the sample 100-fold in water; if it"s between 15–18 then dilute 10-fold in water. This will reduce the likelihood of PCR-inhibition.
Following cDNA synthesis, primer pools (based on sequences from the ARTIC Network) are used in a high-fidelity multiplex PCR to prepare two pools of 400 bp QIAseq SARS-CoV-2 Primer Panel amplicons. The two enriched pools per sample are then combined into a single tube and then purified. This is then followed by QIAseq FX DNA library construction.
QIAseq FX DNA Library construction
Purified amplicons from a multiplex QIAseq SARS-CoV-2 Primer Panel are converted to Illumina-compatible NGS libraries using our QIAseq FX DNA Library UDI Kits, which provide a fast, fully enzymatic procedure from DNA fragmentation to NGS library.
Purified, target-enriched samples from the QIAseq SARS-CoV-2 Primer Panel are first enzymatically sheared into smaller fragments. The desired median fragment size is 250 bp. The fragmented DNA is then directly end-repaired and an "A" is added to the 3’ ends during the FX reaction, making the DNA fragments ready for adapter ligation. Following this step, Illumina platform-specific adapters are ligated to both ends of the DNA fragments. These adapters contain sequences essential for binding dual bar-coded libraries to a flow cell for sequencing.
Following adapter ligation, the reaction is purified, and any adapter-dimers are removed. This can be automated on various high-throughput automation platforms.
Whole SARS-CoV-2 genome coverage
Based on primer sequences from the ARTIC Network and this publication, the QIAseq SARS-CoV-2 Primer Panel separates 400 bp amplicons into two PCR pools that together cover the entire SARS-CoV-2 genome. Using a QIAseq FX DNA Library UDI Kit, the amplicons from the QIAseq SARS-CoV-2 Primer Panel are brought within the length requirements to perform sequencing on Illumina platforms.
The QIAseq SARS-CoV-2 Primer Panel can be used to generate whole genome coverage of the SARS-CoV-2 viral genome for epidemiological research purposes.
Product Resources
Customers who bought these products also bought
- Cat No./ID:333937
QIAseq Human Exome Kit (24)
For 3 hybridization capture reactions to process up to 24 Illumina-compatible libraries in pools of 8; contains probes, blocking oligos, and reagents for hybrid capture and post-hybrid capture amplification for whole exome enrichment; requires separate purchase of QIAseq FX DNA Library UDI Kit (24), cat. no. 180477
$4,680.00Add To Cart - Cat No./ID:180475
QIAseq FX DNA Library Kit (96)
Buffers and reagents for DNA fragmentation (including end repair and A-addition), ligation and library amplification; for use with Illumina instruments; includes a plate containing 96 combinatorial dual index adapters with different bar codes (pierceable foil seal, allowing usage of defined parts of plate)
$3,423.00Add To Cart - Cat No./ID:180477
QIAseq FX DNA Library UDI Kit (24)
Buffers and reagents for DNA fragmentation (including end repair and A-addition), ligation and library amplification; for use with Illumina instruments; includes a plate containing 24 Unique Dual Index Y-adapters.
$907.00Add To Cart - Cat No./ID:180312
QIAseq UDI Y-Adapter Kit A (96)
Box containing dual bar-coded Unique Dual Sample Index Y-adapters; plate-format for 96 samples; no library preparation reagents included
$1,440.00Add To Cart - Cat No./ID:180310
QIAseq UDI Y-Adapter Kit (24)
Box containing dual bar-coded Unique Dual Sample Index Y-adapters; plate-format for 24 samples
$375.00Add To Cart - Cat No./ID:180479
QIAseq FX DNA Library UDI-A Kit (96)
Buffers and reagents for DNA fragmentation (including end repair and A-addition), ligation and library amplification; for use with Illumina instruments; includes a plate containing 96 Unique Dual Index Y-adapters
$3,594.00Add To Cart - Cat No./ID:395092
AdnaTest CTC-Select
For immunomagnetic enrichment of circulating tumor cells (CTCs) from human whole blood for 12 preparations.$1,064.00Add To Cart - Cat No./ID:180473
QIAseq FX DNA Library Kit (24)
Buffers and reagents for DNA fragmentation (including end repair and A-addition), ligation and library amplification; for use with Illumina instruments; includes a plate containing 24 combinatorial dual index adapters with different bar codes (pierceable foil seal, allowing usage of defined parts of plate)
$864.00Add To Cart - Cat No./ID:206442
UltraRun LongRange PCR Kit (100)
For 100 x 20 µl PCR reactions: 1 x 500 µl UltraRun LongRange PCR Master Mix (4x), 1 x 200 µl Template Tracer (25x), 1 x 50 µl Master Mix Tracer (125x), 1 x 2 ml Q-Solution (5x), 1 x 1.9 ml RNase-free Water
$155.00Add To Cart - Cat No./ID:13997-50
RNeasy PowerClean Pro Cleanup Kit (50)
For the removal of inhibitors from purified RNA in just 7 minutes$252.00Add To Cart - Cat No./ID:333314
QIAseq Library Quant Assay Kit
1 tube of Primer Mix (500 µl), 1 bottle of Dilution Buffer (30 ml), 1 tube DNA Standard (100 µl), and 5 tubes GeneRead qPCR SYBR Green (1.35 ml) for sample library quantification prior to NGSSelect Targets - Cat No./ID:19311
PowerBead Pro Plates (4)
Bead plates ready for rapid and reliable biological sample lysis from a wide variety of starting materials$361.00Add To Cart - Cat No./ID:990610
Filter-Tips, OnCor C, 200 µl (10 x 96)
Disposable filter-tips; for use with QIAcube HT and QIAxtractor$169.00Add To Cart - Cat No./ID:208356
QuantiNova Probe RT-PCR Kit (2500)
For 2500 x 20 µl reactions: 15 x 1.7 ml QuantiNova Probe RT-PCR Master Mix, 5 x 100 µl QuantiNova Probe RT Mix, 5 x 100 µl Internal Control RNA , 5 x 500 µl Yellow Template Dilution buffer, 5 x 1 ml ROX Reference Dye, 10 x 1.9 µl RNase-Free Water$2,733.00Add To Cart - Cat No./ID:990556
Reagent Trough (with lid), 170 ml
Box of 20 plus lid; liquid reservoirs; used with Reagent Trough R1 Position Plate and Reagent Trough SBS Plate$128.00Add To Cart - Cat No./ID:47021
DNeasy 96 PowerSoil Pro QIAcube HT Kit (5)
For the high-throughputisolation of microbial genomic DNA from all soil types, optimized for the QIAcube.$1,963.00Add To Cart - Cat No./ID:990554
Reagent Trough (with lid), 70 ml
Box of 10 plus lid; liquid reservoirs; used with Reagent Trough R1 Position Plate and Reagent Trough SBS Plate$79.60Add To Cart - Cat No./ID:19585
S-Blocks (24)
96-well blocks with 2.2 ml wells, 24 per case$348.00Add To Cart - Cat No./ID:217084
miRNeasy Micro Kit (50)
For 50 total RNA preps: 50 RNeasy MinElute Spin Columns, Collection Tubes (1.5 ml and 2 ml), QIAzol Lysis Reagent, RNase-Free Reagents and Buffers$411.00Add To Cart - Cat No./ID:55284
QIAamp MinElute ccfDNA Midi Kit (50)
For 50 preps (4 or 5 ml sample input volume each): QIAamp UCP MinElute Columns, QIAGEN Proteinase K, Magnetic Bead Suspension, Buffers, Bead Elution Tubes, and Collection Tubes (1.5 ml and 2 ml)$977.00Add To Cart