QIAsymphony RGQ MDx (US)
For in vitro diagnostic (IVD) use in performing FDA cleared or approved nucleic acid testing in clinical laboratories
- IVD workflow optimization and utility
- Maximized ease-of-use and convenience
QIAGEN"spremier sample-to-result in vitro diagnostic workflow solution comprises the QIAsymphony SP, QIAsymphony AS, and Rotor-Gene Q MDx instruments, and Rotor-Gene AssayManager software. QIAsymphony SP/AS is an integrated automated system for performing sample preparation using QIAsymphony DSP (Diagnostic Sample Prep) Kitsand subsequentassay setups. Rotor-Gene Q MDx is a real-time nucleic acid amplification and detection systemthat measures nucleic acid signals from amplified DNA using fluorescent detection.Rotor-Gene AssayManager softwareperforms automated analysis and data interpretation and isusedin combination withQIAsymphony RGQ MDx (US)instrumentsto perform FDA cleared or approved nucleic acid testing. QIAGENplans to expand the capabilities ofQIAsymphony RGQ MDx (US)with new features, IVD assay menus, and workflows.
- Buy Products
- Product Details
- Specifications
Buy Products
Cat No./ID:9002341 QIAsymphony RGQ MDx (US) Inquire QIAsymphony SP, QIAsymphony AS, Rotor-Gene Q MDx, Rotor-Gene AssayManager software; includes required accessories and consumables, installation, and training; includes 1-year warranty on parts and labor |
Cat No./ID:9020246 QIAsymphony Cabinet SP/AS Inquire Accessory for correct positioning of the QIAsymphony SP/AS instruments |
Cat No./ID:9022910 artus basic (US) plug-in for Rotor-Gene AssayManager Inquire Compact disc (CD) containing artus basic (US) plug-in for Rotor-Gene AssayManager |
Cat No./ID:937036 QIAsymphony DSP Virus/Pathogen Mini Kit $1,103.00 For 192 preps (200 µl each): includes 2 reagent cartridges and enzyme racks and accessories |
The QIAsymphony RGQ MDx system is intended for in vitro diagnostic (IVD) use in performing FDA cleared or approved nucleic acid testing in clinical laboratories. It comprises the QIAsymphony SP, QIAsymphony AS, and Rotor-Gene Q MDx instruments. The QIAsymphony SP is an automated system for performing sample preparation for nucleic acid testing. The QIAsymphony AS is an automated system for performing assay setups for nucleic acid testing. The Rotor-Gene Q MDx is a real-time nucleic acid amplification and detection system which measures nucleic acid signals from amplified DNA using fluorescent detection.
Product Details
QIAsymphony RGQ MDx (US) can save you time by processingas many as72 samples, from sample to result, in one integrated run.
QIAsymphony RGQ MDx (US) is the integrated system to maximize your efficiency and optimize your IVD workflows, from sample to result. QIAsymphony RGQ MDx (US) synergizes the automated sample preparation and assay setup on the QIAsymphony SP/AS with manual transfer to the Rotor-Gene Q MDxfor detection. The QIAsymphony SP,together with the QIAsymphony DSP Virus/Pathogen Kits,automates sample preparation and the QIAsymphony AS delivers reliable and reproducibleIVD assay setup. Rotor-Gene AssayManager provides fully automated analysis and interpretation of results,minimizes human error, and delivers results you can trust.
Kits | Instrument | Method |
---|---|---|
QIAsymphony DSP Virus/Pathogen Kits | QIAsymphony RGQ MDx (US) | Purification of bacterial DNA from avariety of sample types |
artus C. difficile QS-RGQ MDx Kit | QIAsymphony RGQ MDx (US) | Direct qualitative detection of toxigenic C. difficile toxin A and toxin B genes |
The QIAsymphony RGQ MDx (US)workflow starts with purification of nucleic acids on the QIAsymphony SP instrument. The eluates, containing purified nucleic acids from the sample preparation procedure, are automaticallytransferred to the QIAsymphony AS module, which performs assay setup. The assays are then manually transferred to the Rotor-Gene Q MDxforreal-time amplification, detection,and data analysis.
The QIAsymphony RGQ MDx (US)is theplatform forperforming FDA clearedor approved nucleic acid tests.
Future applications will focus on:
- Menu expansion for pathogen detection
- Tests for personalized healthcare
- Pharma co-developed tests
Specifications
Features | Specifications |
Altitude | Up to 2000 m (6500 ft) |
Elution volume | QIAsymphony SP — application dependent |
Features | QIAsymphony SP/AS — compatible with as many as 4 Rotor-Gene Q MDx instruments Rotor-Gene Q MDx — dynamic range, 10 orders of magnitude |
Heat dissipation/thermal load | Rotor-Gene Q MDx — average, 0.183 kW (632 BTU/hour); peak, 0.458 kW (1578 BTU/hour) |
Humidity | QIAsymphony SP/AS — relative humidity of 20–75% (noncondensing); maximum 75% relative humidity Rotor-Gene Q MDx — relative humidity of 10–75% (noncondensing) |
Input volume | QIAsymphony SP — application dependent |
Instrument dimensions | QIAsymphony SP/AS — QIAsymphony SP, width: 128 cm (50.4 in.), height: 103 cm (40.6 in.), depth: 73 cm (28.7 in.); QIAsymphony AS, width: 59 cm (23.2 in.), height: 103 cm (40.6 in.), depth: 73 cm (28.7 in.); QIAsymphony SP/AS (integrated operation), width: 185 cm (72.8 in.), height: 103 cm (40.6 in.), depth: 73 cm (28.7 in.) Rotor-Gene Q MDx — width, 37 cm (14.6 in.); height, 28.6 cm (11.3 in.); depth (without cables), 42 cm (16.5 in.); depth (door open), 53.8 cm (21.2 in.) |
Kits or Application Packs designed for this instrument | QIAsymphony SP — QIAsymphony DSP Virus/Pathogen Kits QIAsymphony AS — artus C. difficile QS-RGQ MDx Kit Rotor-Gene Q MDx — artus C. dificile QS-RGQ MDx Kit |
Operating temperature | QIAsymphony SP/AS — 18–26°C (64.4–78.8ºF) Rotor-Gene Q MDx — 18–30ºC (64–86ºF) |
Optical System | Rotor-Gene Q MDx — 6 channels; excitation sources: high energy light-emitting diodes; detector: photomultiplier; acquisition time: 4 seconds |
Overvoltage category | II |
Place of operation | For indoor use only |
Pollution level | QIAsymphony SP/AS — 2; Environmental class 3K2 (IEC 60721-3-3); 3M2 (IEC 60721-3-3) Rotor-Gene Q MDx — 2; Environmental class 2K2 (IEC 60721-3-3) |
Power | QIAsymphony SP/AS — 100–240 V AC, 50–60 Hz, 1400 VA, mains supply voltage are not to exceed 10% of nominal supply voltages Rotor-Gene Q MDx — 100–240 V AC, 50–60 Hz, 520 VA (peak); Power consumption 8 VA (standby); Mains supply voltage fluctuations are not to exceed 10% of the nominal supply voltages; F5A 250 V fuse |
Processing | QIAsymphony SP/AS — automated |
Protocols/main application on this instrument | QIAsymphony SP — purification of bacterial nucleic acids from a variety of starting materials QIAsymphony AS — PCR setup Rotor-Gene Q MDx — qualitative detection of toxigenic C. difficile toxin A and toxin B genes |
Samples per run (throughput) | QIAsymphony SP — 1–96 samples in batches of 24 Rotor-Gene Q MDx — Strip Tubes 0.1 ml (4 tubes) - 72 samples/run |
Software | Rotor-Gene Q MDx — Rotor-Gene Q software 2.1.0 or higher, supplied on the installation CD provided; Rotor-Gene AssayManager version 1.0 or higher |
Storage temperature | QIAsymphony SP/AS — 5–40°C (41ºF to 104ºF) in manufacturer"s package Rotor-Gene Q MDx — 15 to 30ºC (59ºF to 86ºF) in manufacturer’s package; max. 75% relative humidity (noncondensing); environmental class 1K2 (IEC 60721-3-1) |
Technology | QIAsymphony SP — QIAGEN magnetic-particles chemistry Rotor-Gene Q MDx — real-time PCR cycler |
Thermal performance | Rotor-Gene Q MDx — temperature range, 35°C to 99°C (95°F to 210.2°F); temperature accuracy, ±0.5°C; temperature resolution, ±0.02°C (smallest programmable increment); temperature uniformity, ±0.02°C (standard deviation) |
Transportation conditions | QIAsymphony SP/AS — –25 to 70°C (–13ºF to 158ºF) in manufacturer"s package Rotor-Gene Q MDx — –25 to 60ºC (–13ºF to 140ºF) in manufacturer’s package; max. 75% relative humidity (noncondensing); environmental class 2K2 (IEC 60721-3-2) |
Typical run time | Rotor-Gene Q MDx — 40 cycles in 45 min with the QIAGEN RG Kits (assay dependent) |
Warranty | Rotor-Gene Q MDx — 1 year on instrument; lifetime guarantee on excitation LEDs |
Weight | QIAsymphony SP, 175 kg (385.8 lb.); QIAsymphony AS, 90 kg (198 lb.); QIAsymphony SP/AS (integrated operation), 265 kg (584 lb.); Rotor-Gene Q MDx, 12.5 kg (27.6 lb.) (standard configuration) |
Product Resources
Customers who bought these products also bought
- Cat No./ID:997024
Filter-Tips, 1500 µl, Qsym SP (1024)
Disposable Filter-Tips, racked; (8 x 128). For use with the QIAsymphony SP/AS instruments$129.00Add To Cart - Cat No./ID:997002
Sample Prep Cartridges, 8-well (336)
8-well sample prep cartridges for use with the QIAsymphony SP$146.00Add To Cart - Cat No./ID:997004
8-Rod Covers (144)
8-Rod Covers for use with the QIAsymphony SP$103.00Add To Cart - Cat No./ID:9018089
Cooling Adapter, Reagent Holder 2, Qsym
Adapter for holding 18 x 2 ml conical tubes, 2 x 5 ml conical tubes, and 2 x Reagent Bottles, 30 ml; for use with the QIAsymphony AS (software version 3.1 or higher)$950.00Add To Cart - Cat No./ID:990332
Filter-Tips, 200 µl, (1024)
Disposable Filter-Tips, racked; (8 x 128). For use with the QIAcube and the QIAsymphony SP/AS instruments$104.00Add To Cart - Cat No./ID:9242083
Insert, 2.0ml v2, samplecarr. (24), Qsym
Secondary tube adapter (for 2 ml screw-cap tubes, tube insert 3b) for use with the QIAsymphony SP tube carrier$152.00Add To Cart - Cat No./ID:19588
Elution Microtubes CL (24 x 96)
Nonsterile polypropylene tubes (0.85 ml maximum capacity, less than 0.7 ml storage capacity, 0.4 ml elution capacity); 2304 in racks of 96; includes cap strips$624.00Add To Cart - Cat No./ID:9018092
Cooling Adapter, RG Strip Tubes 72, Qsym
Adapter for holding 18 strips of 4 tubes; for use with the QIAsymphony AS (software version 3.1 or higher)$1,335.00Add To Cart - Cat No./ID:939016
Buffer ATL (4 x 50 ml)
4 x 50 ml lysis buffer for use in purification of nucleic acids using QIAsymphony DSP Virus/Pathogen Kitsand the QIAsymphony DSP DNA Mini Kit$114.00Add To Cart - Cat No./ID:9242057
Tube Insert, 11 mm, Revision, sample carrier, Qsym (24)
Primary tube adapter (11 mm, with tube insert 2A) for use with the QIAsymphony SP tube carrier (all software versions)$248.00Add To Cart - Cat No./ID:997120
Filter-Tips, 50 µl, Qsym AS (1024)
Sterile, Disposable Filter-Tips, racked; (8 x 128); for use with the QIAsymphony AS$208.00Add To Cart - Cat No./ID:937236
QIAsymphony DSP DNA Mini Kit (192)
For 192 preps of 200 µl each: Includes 2 reagent cartridges and enzyme racks and accessories.$955.00Add To Cart - Cat No./ID:937055
QIAsymphony DSP Virus/Pathogen Midi Kit
For 96 preps (1000 µl each): includes 2 reagent cartridges and enzyme racks and accessories$857.00Add To Cart - Cat No./ID:9242058
Tube Insert, 13 mm, sample carrier, Qsym (24)
Primary tube adapter (13 mm, with tube insert 1A) for use with the QIAsymphony SP tube carrier (all software versions)$254.00Add To Cart - Cat No./ID:939011
Buffer ATL (4 x 50 ml)
4 x 50 ml Tissue Lysis Buffer for use in purification of nucleic acids$117.00Add To Cart - Cat No./ID:9242204
Adapter 2 x Rotor-Disc, Qsym
Adapter for holding up to 2 x Rotor-Disc 72 on Rotor-Disc 72 Loading Blocks; for use with the QIAsymphony AS (software version 3.1 or higher)$481.00Add To Cart - Cat No./ID:997102
Tubes, conical, 2 ml, Qsym AS (500)
Conical tubes (2 ml) for holding reagent; for use with the QIAsymphony AS$131.00Add To Cart - Cat No./ID:9018937
Adapter, Light Cycler 480 96-Well Plate
For use with the Roche LightCycler 480; 96-well plate; wells hold 10–100 µl; plate has an orientation pin and a “front” indicator$413.00Add To Cart - Cat No./ID:9021670
Adapter, tubes, 2 ml, v2, Qsym
Non-cooling adapter for 2 ml screw-cap tubes (new version; with bar code)$1,765.00Add To Cart - Cat No./ID:981103
Strip Tubes and Caps, 0.1 ml (250)
250 strips of 4 tubes and caps for 1000 reactions of 10–50 µl$250.00Add To Cart