4000-520-616
欢迎来到免疫在线!(蚂蚁淘生物旗下平台)  请登录 |  免费注册 |  询价篮
主营:主营:分子类化合物
咨询热线电话
4000-520-616
当前位置: 首页 > 产品中心 > peptide > Qiagen/QIAsymphony RGQ/9001850
商品详细Qiagen/QIAsymphony RGQ/9001850
Qiagen/QIAsymphony RGQ/9001850
Qiagen/QIAsymphony RGQ/9001850
商品编号: 9001850
品牌: Qiagen
市场价: ¥0.00
美元价: 0.00
产地: 美国(厂家直采)
公司:
产品分类: 多肽合成
公司分类: peptide
联系Q Q: 3392242852
电话号码: 4000-520-616
电子邮箱: info@ebiomall.com
商品介绍

QIAsymphony RGQ

Request Demo
Product picture

Integrated automated sample preparation and assay setup,withmanual transfer to the detection unit, for all molecular testing needs

  • Unprecedented flexibility
  • Workflow optimization and utility
  • Maximized ease-of-use and convenience
  • Laboratory-developed tests
  • Designed for largest range of applications

QIAGEN"spremier sample-to-result workflow solution comprises the QIAsymphony SPfor sample preparation, the QIAsymphony AS for assay setup, and a broad range of ready-to-use assays on the Rotor-Gene Q real-time PCR cycler.QIAGEN continues to expand the QIAsymphony series with new features, assay menus, and workflows.

Explore thevirtual demoto learn more about QIAsymphony RGQ.
  • Buy Products
  • Product Details
  • Specifications
  • Product Resources

Buy Products

Cat No./ID:9001850
QIAsymphony RGQ, System
Inquire
QIAsymphony SP, QIAsymphony AS, Rotor-Gene Q 5plex HRM; includes required accessories and consumables, installation, and training; includes 1-year warranty on parts and labor
Cat No./ID:9020246
QIAsymphony Cabinet SP/AS
Inquire
Accessory for correct positioning of the QIAsymphony SP/AS instruments

The QIAsymphony SP is intended to be used only in combination with QIAsymphony Kits indicated for use with the QIAsymphony SP for the applications described in the kit handbooks. If used in combination with QIAGEN kits indicated for use with the QIAsymphony AS instrument, the QIAsymphony AS is intended for the applications described in the respective QIAGEN kit handbooks. If the QIAsymphony AS instrument is used with kits other than QIAGEN kits, it is the users responsibility to validate the performance of such product combination for any particular application. The Rotor-Gene Q, if used in combination with QIAGEN kits indicated for use with the Rotor-Gene Q instrument, is intended for the applications described in the respective QIAGEN kits handbooks. If the Rotor-Gene Q instrument is used with kits other than QIAGEN kits, it is the users responsibility to validate the performance of such product combination for any particular application..

Product Details

9
QIAsymphony workflows.

There are 2 modes of system operation: integrated or independent.

Principle

QIAsymphony RGQ can save you time by processing up to96 samples, from sample to result, in one integrated run. A dedicated range of kits enable open or closed systems for molecular testing.

QIAsymphony RGQ is the integrated system to maximize your efficiency and optimize your workflows, from sample to result. QIAsymphony RGQ synergizes the automated sample preparation and assay setup on the QIAsymphony SP/AS with manual transfer to the trusted Rotor-Gene Q for detection. The QIAsymphony SP automates sample preparation from a wide range of sample types. The QIAsymphony AS delivers highly reliable and reproducible PCR assay setup and ishighly suitedfor laboratories that perform complex PCR-based molecular testing on a day-to-day basis. The QIAsymphony AS enables setup of multiple assays per run or sample and supports laboratory-developed tests for fast implementation of key workflows in your laboratory. The Rotor-Gene Q enables sensitive, precise real-time PCR analysis.

Kits forlaboratory-developed testson the QIAsymphony RGQ
Kits Instrument Method
QIAsymphony DSP AXpH DNA Kit QIAsymphony SP Purification of DNA from liquid-based cytology media
QIAsymphony DSP DNA Kits QIAsymphony SP Purification of DNA from human whole blood, buffy coat, tissues, FFPE tissues, cultured cells and bacterial cultures, as well as viral DNA from human whole blood
QIAsymphony DSP Virus/Pathogen Kits QIAsymphony SP Purification of viral nucleic acids or bacterial DNA from a broad range of sample types
QuantiFast Pathogen +IC Kits QIAsymphony AS Multiplex real-time PCR and RT-PCR using sequence-specific probes
QuantiTect Virus Kits QIAsymphony AS Highly sensitive detection of multiple viral DNA and RNA targets in the same tube
QuantiTect Probe RT-PCR Kit QIAsymphony AS Quantitative, real-time one-step RT-PCR using sequence-specific probes
Rotor-Gene Probe RT-PCRKit QIAsymphony AS One-step RT-PCR; probe (singleplex)
Rotor-Gene MultiplexRT-PCRKit QIAsymphony AS PCR and two-step RT-PCR; probe (multiplex)

Procedure

The QIAsymphony RGQ workflow starts with purification of nucleic acids on the QIAsymphony SP instrument. The eluates, containing purified nucleic acids from the sample preparation procedure, are transferred to the QIAsymphony AS module, which performs assay setup. The assays are then manually transferred to the Rotor-Gene Q for PCR and data analysis.

To suit individual workflow requirements, there are 2 modes of system operation: integrated or independent. In the integrated mode, samples processed on the QIAsymphony SP are transferredautomatically to the QIAsymphony AS, reducing manual handling steps and documentation. For added flexibility, the QIAsymphony SP and AS can also be operated independently of each other in independent mode. See "QIAsymphony workflows".

Applications

The QIAsymphony RGQ is the most versatile system for all molecular testing needs— today and tomorrow. The QIAsymphony RGQ allows consolidation of commercial assays, as well as in-house–developed tests, on a single platform.

Future applications will focus on:

  • Menu expansion for pathogen detection and genetic testing
  • Tests for personalized healthcare
  • Pharma co-developed tests
  • Tests developed in your lab community

Specifications

Features
Specifications
Elution volumeQIAsymphony SP — 30–500 µl (application dependent)
FeaturesRotor-Gene Q — dynamic range, 10 orders of magnitude
Heat dissipation/thermal loadRotor-Gene Q — average, 0.183 kW (632 BTU/hour); peak, 0.458 kW (1578 BTU/hour)
HumidityQIAsymphony SP/AS — relative humidity of 15–75% (noncondensing); maximum 75% relative humidity for temperatures up to 31°C, decreasing linearly to 50% humidity at 32°C Rotor-Gene Q — relative humidity of 10–75% (noncondensing)
Input volumeQIAsymphony SP — minimum input volume: 200 µl (application dependent)
Instrument dimensionsQIAsymphony SP/AS — QIAsymphony SP, 128 x 103 x 73 cm; QIAsymphony AS, 59 x 103 x 73 cm; QIAsymphony SP/AS (integrated operation), 185 x 103 x 73 cm Rotor-Gene Q — width, 37 cm (14.6 in.); height, 28.6 cm (11.3 in.); depth (without cables), 42 cm (16.5 in.); depth (door open), 53.8 cm (21.2 in.)
Kits or Application Packs designed for this instrumentQIAsymphony SP — QIAsymphony DSP Virus/Pathogen Kits and other QIAsymphony Kits; QIAsymphony AS — artus QS-RGQ Kits (not available in all countries), Rotor-Gene Kits and other QIAGEN real-time and end-point PCR kits Rotor-Gene Q — artus QS-RGQ Kits (not available in all countries), RG SYBR Green PCR Kits; RG SYBR Green RT-PCR Kit; RG Probe PCR Kits; RG Probe RT-PCR Kit; RG Multiplex PCR Kit
Operating temperatureQIAsymphony SP/AS — 15–32°C (59–89.6ºF) Rotor-Gene Q — 18–30ºC (64–86ºF)
Optical SystemRotor-Gene Q — up to 6 channels spanning UV to infra-red wavelengths; excitation sources: high energy light-emitting diodes; detector: photomultiplier; acquisition time: 4 s; the software allows to create new excitation/detection wavelength combinations
Overvoltage categoryII
Place of operationFor indoor use only
Pollution levelQIAsymphony SP/AS — 2 Rotor-Gene Q — 2; Environmental class 3K2 (IEC 60721-3-3)
PowerQIAsymphony SP/AS — 100–240 V AC, 50–60 Hz, 1400 VA, mains supply voltage are not to exceed 10% of nominal supply voltages Rotor-Gene Q — 100–240 V AC, 50–60 Hz, 520 VA (peak); Power consumption 8 VA (standby); Mains supply voltage fluctuations are not to exceed 10% of the nominal supply voltages; F5A 250 V fuse
ProcessingQIAsymphony SP/AS — automated
Protocols/main application on this instrumentQIAsymphony SP — purification of DNA, RNA, and bacterial and viral nucleic acids from a wide range of starting materials QIAsymphony AS — PCR setup Rotor-Gene Q — gene expression analysis, microRNA detection, virus detection, SNP genotyping, SNP genotyping, High Resolution Melt analysis (HRM)
Samples per run (throughput)QIAsymphony SP — 1–96 samples in batches of 24 Rotor-Gene Q — tubes 0.2 ml; strip tubes 0.1 ml (4 tubes); Rotor-Disc 72; Rotor-Disc 100; up to 100 samples per run using a Rotor-Disc 100
SoftwareRotor-Gene Q — Rotor-Gene Q software, supplied on the provided installation CD
Storage temperatureQIAsymphony SP/AS — 5–40°C (41ºF to 104ºF) in manufacturer"s package Rotor-Gene Q — 15 to 30ºC (59ºF to 86ºF) in manufacturer’s package; max. 75% relative humidity (noncondensing); environmental class 1K2 (IEC 60721-3-1)
TechnologyQIAsymphony SP — QIAGEN magnetic-particles chemistry Rotor-Gene Q — real-time PCR cycler
Thermal performanceRotor-Gene Q — temperature range, 35 to 99ºC; temperature accuracy, ±0.5ºC (type, measured 30 seconds after clock start); temperature resolution, ±0.02ºC (smallest programmable increment); temperature uniformity, ±0.02ºC; ramp rate (peak ramp rates, air), >15ºC/s heating, >20ºC/s cooling
Transportation conditionsQIAsymphony SP/AS — –25 to 70°C (–13ºF to 158ºF) in manufacturer"s package Rotor-Gene Q — –25 to 60ºC (–13ºF to 140ºF) in manufacturer’s package; max. 75% relative humidity (noncondensing); environmental class 2K2 (IEC 60721-3-2)
Typical run timeRotor-Gene Q — 40 cycles in 45 min with the QIAGEN RG Kits (assay dependent)
WarrantyRotor-Gene Q — 1 year on instrument; lifetime guarantee on excitation LEDs
WeightQIAsymphony SP, 175 kg; QIAsymphony AS, 90 kg; QIAsymphony SP/AS (integrated operation), 265 kg; Rotor-Gene Q, 12.5 kg (27.6 lb.) (standard configuration)

Product Resources

You are not authorized to download the resource

Brochures & Guides (1)
  • Sort options
    • Sort alphabetically
(EN) - QIAsymphony RGQ — Pure Performance
Show details
FAQs (65)
  • Sort options
    • Sort alphabetically
There is no barcode on the QIAsymphony cooling adapter, and the instrument asks for one.What do you suggest I do?
FAQ ID - 3532
View
The QIAsymphony RNA kit uses RLT plus as lysis buffer. Can samples lysed in RLT and then stored in the freezer be used on the QIAsymphony?
FAQ ID - 3533
View
What sample types can be processed using the tissue protocols for DNA extraction on the QIAsymphony SP?
FAQ ID -1915
View
Do samples require pretreatment before loading onto the QIAsymphony SP for DNA extraction?
FAQ ID -1916
View
How much starting material can be used with the QIAsymphony DNA Mini Kit on the QIAsymphony SP?
FAQ ID -1917
View
Does an internal control have to be used with the QIAsymphony Virus Blood 200 Protocol?
FAQ ID -2162
View
What RNA elution volumes are available with the QIAsymphony RNA Kit?
FAQ ID -1943
View
What are the recommended lysis times for tissue samples on the QIAsymphony SP?
FAQ ID -2993
View
Is mitochondrial DNA isolated with the QIAsymphony DNA Investigator Kit on the QIAsymphony SP?
FAQ ID -2030
View
Can solid samples be processed with the QIAsymphony DNA Investigator Kit on the instrument?
FAQ ID -2027
View
How long can homogenates remain on the QIAsymphony SP without risk of RNA degradation?
FAQ ID -1941
View
Does an internal control have to be included for each QIAsymphony Virus/Bacteria protocol run?
FAQ ID -2040
View
What sample types can be processed using the QIAsymphony Virus/Bacteria protocols?
FAQ ID -2036
View
What are the dimensions and weight of the QIAsymphony SP System?
FAQ ID -1901
View
What is elution Buffer ATE of the QIAsymphony DNA Investigator Kit?
FAQ ID -2029
View
What is the maximum DNA yield from forensic samples processed with the QIAsymphony SP?
FAQ ID -2028
View
What are the expected yields of total RNA isolated with the QIAsymphony SP?
FAQ ID -1942
View
How should samples be stored before purification using the Virus Blood 200 Protocol on the QIAsymphony?
FAQ ID -2157
View
What is the target nucleic acid for the Virus Blood 200 Protocol on the QIAsymphony?
FAQ ID -2158
View
Will mitochondrial DNA also be isolated using the DNA Tissue protocols on the QIAsymphony SP?
FAQ ID -1921
View
Are there any specific cleaning solutions recommended for the QIAsymphony SP?
FAQ ID -1913
View
What sample types should be processed with the High Content (HC) protocol for DNA extraction on the QIAsymphony SP?
FAQ ID -1918
View
Is RNA co-purified with DNA using QIAsymphony DNA Tissue protocols?
FAQ ID -1920
View
What are the expected DNA yields from tissue processed on the QIAsymphony SP?
FAQ ID -1919
View
Do QIAsymphony Virus/Bacteria samples require pretreatment before they are loaded onto the instrument?
FAQ ID -2039
View
Can the QIAsymphony RNA Kit be used to purify RNA from blood?
FAQ ID -1945
View
What are the expected DNA yields from tissue processed on the QIAsymphony SP?
FAQ ID -2990
View
Which QIAsymphony Virus/Bacteria Kit size should be used for each protocol?
FAQ ID -2038
View
Which sample types can be processed using the QIAsymphony Virus Blood 200 protocol?
FAQ ID -2154
View
What sample types can be processed using the tissue protocols and the QIAsymphony DSP DNA Mini Kit?
FAQ ID -2925
View
How should DNA isolated on the QIAsymphony be stored?
FAQ ID -2165
View
What sample volumes can be used with the Virus Blood 200 Protocol on the QIAsymphony?
FAQ ID -2156
View
What sample input volumes can be used on the QIAsymphony SP?
FAQ ID -1907
View
What are the starting volumes of homogenate for RNA extraction on the QIAsymphony SP?
FAQ ID -1939
View
How does magnetic-particle carry-over in QIAsymphony eluates need to be handled?
FAQ ID -2166
View
Why do casework-sample protocols for the QIAsymphony DNA Investigator Kit start with different lysate volumes (200 µl, 500 µl, or 1000 µl)?
FAQ ID -2035
View
Can DNA yields be increased by prolonging incubation with proteinase K in Buffer ATL?
FAQ ID -2032
View
Is there a charge for user training on the QIAsymphony SP System?
FAQ ID -1900
View
How does QIAsymphony SP keep cellular samples in suspension prior to pipetting so that samples do not settle?
FAQ ID -1905
View
Will mitochondrial DNA also be isolated using the DNA tissue protocols and QIAsymphony DSP DNA Mini Kit on the QIAsymphony SP?
FAQ ID -2991
View
Why do I have to use an ACS (Assay Control Set)?
FAQ ID -2933
View
Is the QIAsymphony RNA Kit compatible with stabilized samples?
FAQ ID -1944
View
Does the QIAsymphony SP system generate run reports and/or log files?
FAQ ID -1911
View
Can uneven sample numbers be processed on the QIAsymphony SP module?
FAQ ID -1906
View
Do tissue samples require pretreatment before loading onto the QIAsymphony SP for DNA extraction?
FAQ ID -2926
View
Is it possible to modify QIAsymphony protocols?
FAQ ID -1903
View
Which types and amounts of sample material can be processed for RNA extraction on the QIAsymphony SP?
FAQ ID -1937
View
Is sample pretreatment required for purifying RNA on the QIAsymphony SP?
FAQ ID -1938
View
Which elution volumes can be selected using the QIAsymphony Virus Blood 200 protocol?
FAQ ID -2160
View
How can the QIAsymphony SP system be decontaminated?
FAQ ID -1914
View
What kind of samples should be processed using the large-volume protocol with the QIAsymphony DNA Investigator Kit?
FAQ ID -2034
View
How much starting material can be used with the QIAsymphony DSP DNA Mini Kit on the QIAsymphony SP?
FAQ ID -2927
View
Can the QIAsymphony SP Module be connected to a laboratory information management system (LIMS)?
FAQ ID -1909
View
What sample volumes can be processed with the QIAsymphony Virus/Bacteria Kits?
FAQ ID -2037
View
Do all QIAsymphony DNA Investigator protocols use carrier RNA?
FAQ ID -2033
View
What sample types can be processed using the QIAsymphony DSP Virus/Pathogen protocols?
FAQ ID -2928
View
Can I program my own protocols for the QIAsymphony SP?
FAQ ID -1904
View
What sample types should be processed with the low content (LC) and high content (HC) protocols for DNA extraction on the QIAsymphony SP?
FAQ ID -2989
View
How many samples can be processed per kit or per reagent cartridge for RNA purification on the QIAsymphony SP?
FAQ ID -1940
View
What sample volumes can be used with the tissue HC and LC protocols on the QIAsymphony SP?
FAQ ID -2992
View
Can protocol runs on the QIAsymphony SP be interrupted and resumed?
FAQ ID -1912
View
How many samples can be processed with the QIAsymphony DNA Mini Kit and the Virus Blood 200 protocol?
FAQ ID -2159
View
Does carrier RNA have to be added using the QIAsymphony Virus Blood 200 Protocol?
FAQ ID -2163
View
What is the range of elution volumes on the QIAsymphony SP?
FAQ ID -1908
View
Should sample lysate volumes be exactly 200 µl, 500 µl, or 1000 µl when loaded on the QIAsymphony SP?
FAQ ID -2031
View
Kit Handbooks (1)
  • Sort options
    • Sort alphabetically
artus EBV QS-RGQ Kit Handbook
artus EBV QS-RGQ Kit Handbook
Show details
Labware Files and Documents (1)
  • Sort options
    • Sort alphabetically
(EN) - QIAsymphony SP/AS adapters and tube inserts
Show details
Application/Protocol Documents (28)
  • Sort options
    • Sort alphabetically
(EN) - Certal Residual RGQ-5-plex-HRM RD72 V2
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
(EN) - Certal Residual RGQ-5-plex-HRM RS4 V2
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
(EN) - QIAGEN-PCR-96 (15+10) 1ch V3
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
(EN) - QIAGEN-PCR-96 (40+10) 4ch V3
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
(EN) - QIAGEN-PCR-96 (45+5) 4ch V3
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
(EN) - QIAGEN-PCR-LC (15+5) 1ch V3
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
(EN) - QIAGEN-PCR-RGQ (15+10) 1ch V3
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
(EN) - QIAGEN-PCR-RGQ (20+5) 1ch V3
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
(EN) - QIAGEN-PCR-RGQ RD72 (20+5) 1ch V3
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
Settings to run artus QS-RGQ Kits (Rotor-Gene Q software 2.1, or higher)
Show details
(EN) - mericon Campylobacter spp QIAGEN-PCR-96 V1
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
(EN) - mericon Campylobacter spp QS-RGQ RD72 V1
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
(EN) - mericon Campylobacter spp QS-RGQ RS V1
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
(EN) - mericon Cronobacter spp QIAGEN-PCR-96 V1
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
(EN) - mericon Cronobacter spp QS-RGQ RD72 V1
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
(EN) - mericon Cronobacter spp QS-RGQ RS V1
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
(EN) - mericon Listeria spp QIAGEN-PCR-96 V1
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
(EN) - mericon Listeria spp QS-RGQ RD72 V1
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
(EN) - mericon Listeria spp QS-RGQ RS V1
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
(EN) - mericon Campylobacter triple QIAGEN-PCR-96 V1
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
(EN) - mericon Campylobacter triple QS-RGQ RD72 V1
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
(EN) - mericon Campylobacter triple QS-RGQ RS V1
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
(EN) - mericon L. monocytogenes QIAGEN-PCR-96 V3
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
(EN) - mericon L. monocytogenes QS-RGQ RD72 V3
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
(EN) - mericon L. monocytogenes QS-RGQ RS V3
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
(EN) - mericon Salmonella spp QIAGEN-PCR-96 V3
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
(EN) - mericon Salmonella spp QS-RGQ RD72 V3
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
(EN) - mericon Salmonella spp QS-RGQ RS V3
For use with the QIAsymphony AS (software version 4.0 or higher)
Show details
Instrument Technical Documents (10)
  • Sort options
    • Sort alphabetically
(EN) - QIAsymphony Cabinet SP/AS Specifications
QIAsymphony Cabinet SP/AS documents
Show details
(EN) - QIAsymphony Cabinet SP/AS User Guide
QIAsymphony Cabinet SP/AS document
Show details
QIAsymphony SP Recovery Procedure for DNA Investigator Applications (software version 4.0 or higher and HID 1.0)
QIAsymphony SP recovery procedures for DNA Investigator applications for software version 4.0 and HID 1.0
Show details
QIAsymphony SP Recovery Procedure for DNA Investigator HE (High Efficiency) Applications (software version 4.0 or higher and HID 1.0)
QIAsymphony SP recovery procedures for DNA Investigator applications for software version 4.0 and HID 1.0
Show details
QIAsymphony SP Recovery Procedure for DNA Investigator ADV (Advanced) HE (High Efficiency) Applications (software version 4.0 or higher and HID 1.0)
QIAsymphony SP recovery procedures for DNA Investigator applications for software version 4.0 and HID 1.0
Show details
QIAsymphony SP Recovery Procedure for DNA Investigator ADV (Advanced) Applications (software version 4.0 or higher and HID 1.0)
QIAsymphony SP recovery procedures for DNA Investigator applications for software version 4.0 and HID 1.0
Show details
(EN) - Differences between QIAsymphony software versions 4.0.2 and 4.0.3
Differences between QIAsymphony software versions
Show details
Differences between QIAsymphony software versions 4.0.3/4.1 and 5.0.3
Show details
QIAsymphony File Transfer User Guide
For use with QIAsymphony SP/AS instruments (software version 5.0)
Show details
(EN) - QIAsymphony File Transfer User Guide
Software document for QIAsymphony software version 4.0.1
Show details
Instrument User Manuals (7)
  • Sort options
    • Sort alphabetically
(EN) - Rotor-Gene Q User Manual
For Rotor-Gene Q instruments using Rotor-Gene Q Software version 2.3.4
Show details
Rotor-Gene Q Important Note
Guideline for ISO 20836:2020
Show details
QIAsymphony SP/AS Consolidated Operating Guide
For use with QIAsymphony SP/AS instruments (software version 5.0)
Show details
QIAsymphony SP/AS General Description
For use with QIAsymphony SP/AS instruments (software version 5.0)
Show details
QIAsymphony SP/AS User Manual - Operating the QIAsymphony SP
For use with QIAsymphony SP/AS instruments (software version 5.0)
Show details
QIAsymphony SP/AS User Manual - Operating the QIAsymphony AS
For use with QIAsymphony SP/AS instruments (software version 5.0)
Show details
QIAsymphony Management Console User Manual
For use with QIAsymphony SP/AS instruments (software version 5.0)
Show details
Protocol Files (6)
  • Sort options
    • Sort alphabetically
(EN) - QIAsymphony V4 AS mericon Protocols
For use with the QIAsymphony SP/AS instruments (software version 4.0 or higher)
Show details
(EN) - QIAsymphony V4 AS QIAGEN PCR Applications
For use with the QIAsymphony SP/AS instruments (software version 4.0 or higher)
Show details
QIAsymphony SP Applications Investigator V5
For use with the QIAsymphony SP/AS instruments (software version 5.0 or higher)
Show details
(EN) - QIAsymphony V4 AS Certal Protocols
For use with the QIAsymphony SP/AS instruments (software version 4.0 or higher)
Show details
(EN) - QIAsymphony V4 AS Installation Protocols
For use with the QIAsymphony SP/AS instruments (software version 4.0 or higher)
Show details
QIAsymphony V5 SP Applications
For use with the QIAsymphony SP/AS instruments (software version 4.0 or higher)
Show details
Supporting Software and Tools (1)
  • Sort options
    • Sort alphabetically
QIAsymphony Management Console
For QIAsymphony software version 5.0.4
Show details
Scientific Posters (2)
  • Sort options
    • Sort alphabetically
(EN) - Development of a new platform for fully automated purification of nucleic acids from a broad spectrum of forensic specimens
Show details
(EN) - Application of a HT magnetic bead-based DNA extraction system to diverse mAb process intermediates
Show details
fragment fix placeholder

Customers who bought these products also bought

  • Cat No./ID:9018089
    /us/products//top-sellers/qiasymphony-spas-accessories/

    Cooling Adapter, Reagent Holder 2, Qsym

    Adapter for holding 18 x 2 ml conical tubes, 2 x 5 ml conical tubes, and 2 x Reagent Bottles, 30 ml; for use with the QIAsymphony AS (software version 3.1 or higher)
    $950.00
    Add To Cart
  • Cat No./ID:9242083
    /us/products//top-sellers/qiasymphony-spas-accessories/

    Insert, 2.0ml v2, samplecarr. (24), Qsym

    Secondary tube adapter (for 2 ml screw-cap tubes, tube insert 3b) for use with the QIAsymphony SP tube carrier
    $152.00
    Add To Cart
  • Cat No./ID:9018092
    /us/products//top-sellers/qiasymphony-spas-accessories/

    Cooling Adapter, RG Strip Tubes 72, Qsym

    Adapter for holding 18 strips of 4 tubes; for use with the QIAsymphony AS (software version 3.1 or higher)
    $1,335.00
    Add To Cart
  • Cat No./ID:9242057
    /us/products//top-sellers/qiasymphony-spas-accessories/

    Tube Insert, 11 mm, Revision, sample carrier, Qsym (24)

    Primary tube adapter (11 mm, with tube insert 2A) for use with the QIAsymphony SP tube carrier (all software versions)
    $248.00
    Add To Cart
  • Cat No./ID:9242058
    /us/products//top-sellers/qiasymphony-spas-accessories/

    Tube Insert, 13 mm, sample carrier, Qsym (24)

    Primary tube adapter (13 mm, with tube insert 1A) for use with the QIAsymphony SP tube carrier (all software versions)
    $254.00
    Add To Cart
  • Cat No./ID:9242204
    /us/products//top-sellers/qiasymphony-spas-accessories/

    Adapter 2 x Rotor-Disc, Qsym

    Adapter for holding up to 2 x Rotor-Disc 72 on Rotor-Disc 72 Loading Blocks; for use with the QIAsymphony AS (software version 3.1 or higher)
    $481.00
    Add To Cart
  • Cat No./ID:9018937
    /us/products//instruments-and-automation/accessories/qiagility-accessories/

    Adapter, Light Cycler 480 96-Well Plate

    For use with the Roche LightCycler 480; 96-well plate; wells hold 10–100 µl; plate has an orientation pin and a “front” indicator
    $413.00
    Add To Cart
  • Cat No./ID:9021670
    /us/products//top-sellers/qiasymphony-spas-accessories/

    Adapter, tubes, 2 ml, v2, Qsym

    Non-cooling adapter for 2 ml screw-cap tubes (new version; with bar code)
    $1,765.00
    Add To Cart
  • Cat No./ID:9018090
    /us/products//top-sellers/qiasymphony-spas-accessories/

    Cooling Adapter, Reagent Holder 1, Qsym

    Adapter for holding 18 x 2 ml conical tubes, and 6 x 5 ml conical tubes; for use with the QIAsymphony AS (software version 3.1 or higher)
    $1,308.00
    Add To Cart
  • Cat No./ID:9019873
    /us/products//top-sellers/qiasymphony-spas-accessories/

    Carrier, tubes (1), sample track, Qsym

    Tube carrier for sample input; for use with the QIAsymphony SP
    $503.00
    Add To Cart
品牌介绍
QIAGEN是一家专业化致力于生物分子样品制备解决方案的跨国经营企业,总部位于德国。1984年,QIAGEN在德国成立,1996年在美国纽约纳斯达克上市。QIAGEN拥有超过1000项专利和认可证明,在18个国家设立了分公司,代理商服务国超过40个,在全球有超过400000的用户。QIAGEN提供的产品超过500类,包括各种试剂,耗材和自动化纯化工作站。这些产品用于样品采集,稳定,核酸或蛋白的分离,纯化和检测中,不仅广泛的应用于科研领域的各个方面,在生物技术,制药,法医研究,食品安全检测,畜牧业和分子诊断领域也得到了广泛的应用。QIAGEN产品的卓越品质和在应用中的出色表现使得其成为样品处理中标准的代名词。